Every 50 Hours
1.
Unloading Auger Swivel Joint. Lube bank of three lubrication lines.
IMPORTANT:
Pump 10 to 15 shots of grease into each fitting.
|
2.
Feeder House Upper Drive Sheaves. Rotate sheave for access to two fittings.
3.
Feeder House Reverser Drive Gear Case. Rotate sheaves for access to two fittings.
|
|
AG,OUO1035,1765 -19-23FEB00-1/5
|
4.
Fresh Air Filter. To remove filter, loosen knob (A), remove door and empty tray. Remove wing nut (B) and slide filter out. Clean or replace filter. This filter
|
may require cleaning sooner in very dusty conditions.
|
|
AG,OUO1035,1765 -19-23FEB00-2/5
|
1.
Cleaning Fan Variable Sheaves. Fitting on hub of outer sheave. Rotate sheaves for fitting access.
2.
Cleaning Fan Variable Sheaves. Fitting on hub located on inner sheave. Rotate sheaves for fitting access.
NOTE:
When operating in mud and water grease rear axle spindle bearings and motor pivots at 10
|
hours. In normal conditions grease at 50 hours.
3.
Motor Pivots 2-Speed 4-Wheel Drive (both sides). Lube two fittings.
4.
Heavy Duty Rear Axle Spindles. Lube four fittings (both sides).
|
|
AG,OUO1035,1765 -19-23FEB00-3/5
|
A-Dipstick
| B-Lower Sight Glass
| C-Upper Sight Glass
| D-Drain Plug
|
1.
Mass Flow Sensor. Lower auger and clean mass flow sensor plate.
2.
Two Speed Separator Drive. Remove dipstick (A) and check. Add oil as needed correct level on dipstick.
|
3.
Hydrostatic/Hydraulic Oil Level. Check with header on ground. Oil level must be above lower sight glass (B) and below top of upper sight glass (C). Add oil as needed.
|
|
AG,OUO1035,1765 -19-23FEB00-4/5
|
4.
Radiator, Charge Air Cooler, Oil Cooler and Condenser. Blow compressed air from inside out. Check areas for chaff buildup and clean as needed.
5.
Fuel System Water Separator. Check for water. Loosen plug (D) and drain.
|
6.
Moisture Sensor. Remove cover and clean out moisture sensor.
|
|