Error Codes

  • ER02 - No header connected or invalid header type.
  • ER03 - No corn head connected during deck plate calibration
  • ER21 - CONTOURMASTER ™ angle sensor voltage less than 0.5VDC
  • ER22 - CONTOURMASTER ™ angle sensor voltage greater than 4.5VDC
  • ER23 - CONTOURMASTER ™ angle sensor voltage noisy or changing in an incorrect direction
  • ER24 - CONTOURMASTER ™ angle voltage range less than 2.0VDC
  • ER25 - CONTOURMASTER ™ angle sensor "left" voltage greater than 2.5VDC
  • ER26 - CONTOURMASTER ™ angle sensor "right" voltage less than 2.5VDC
  • ER27 - CONTOURMASTER ™ angle sensor center voltage is not within 0.75VDC of mid-range
  • ER41 - Deck plate position sensor voltage less than 0.5VDC
  • ER42 - Deck plate position sensor voltage greater than 4.5VDC
  • ER43 - Deck plate position sensor voltage noisy or changing in an incorrect direction
  • ER44 - Deck plate position sensor voltage range less than 2.0VDC
  • ER45 - Deck plate position sensor "closed" voltage greater than 2.5VDC
  • ER46 - Deck plate position sensor "opened" voltage less than 2.5VDC
  • ER51 - Header height resume sensor voltage less than 0.5VDC
  • ER52 - Header height resume sensor voltage greater than 4.5VDC
  • ER53 - Header height resume sensor voltage noisy or changing in an incorrect direction
  • ER54 - Header height resume sensor voltage range less than 2.0VDC
  • ER55 - Header height resume sensor "lowered" voltage greater than 2.5VDC
  • ER56 - Header height resume sensor "raised" voltage less than 2.5VDC
  • ER59 - Header height resume sensor has excessive hysteresis
  • ER71 - Left height sensor voltage less than 0.5VDC
  • ER72 - Left height position sensor voltage greater than 4.5VDC
  • ER73 - Left height position sensor voltage noisy or changing in an incorrect direction
  • ER74 - Left height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
  • ER75 - Left height position sensor "lowered" voltage greater than 2.5VDC
  • ER76 - Left height position sensor "raised" voltage less than 2.5VDC
  • ER77 - Left and right height sensor not stopping at same feeder house position
  • ER81 - Right height sensor voltage less than 0.5VDC
  • ER82 - Right height position sensor voltage greater than 4.5VDC
  • ER83 - Right height position sensor voltage noisy or changing in an incorrect direction
  • ER84 - Right height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
  • ER85 - Right height position sensor "lowered" voltage greater than 2.5VDC
  • ER86 - Right height position sensor "raised" voltage less than 2.5VDC
  • ER91 - Flex/belt center header height sensor voltage less than 0.5VDC
  • ER92 - Flex/belt center header height position sensor voltage greater than 4.5VDC
  • ER93 - Flex/belt center header height position sensor voltage noisy or changing in an incorrect direction
  • ER94 - Flex/belt center height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
  • ER95 - Flex/belt center header height position sensor "lowered" voltage greater than 2.5VDC
  • ER96 - Flex/belt center header height position sensor "raised" voltage less than 2.5VDC

CONTOURMASTER is a trademark of Deere & Company.

AG,OUO1035,1382 -19-05JAN00-1/1