Error Codes
ER02 - No header connected or invalid header type.
ER03 - No corn head connected during deck plate calibration
ER21 - CONTOURMASTER angle sensor voltage less than 0.5VDC
ER22 - CONTOURMASTER angle sensor voltage greater than 4.5VDC
ER23 - CONTOURMASTER angle sensor voltage noisy or changing in an incorrect direction
ER24 - CONTOURMASTER angle voltage range less than 2.0VDC
ER25 - CONTOURMASTER angle sensor "left" voltage greater than 2.5VDC
ER26 - CONTOURMASTER angle sensor "right" voltage less than 2.5VDC
ER27 - CONTOURMASTER angle sensor center voltage is not within 0.75VDC of mid-range
ER41 - Deck plate position sensor voltage less than 0.5VDC
ER42 - Deck plate position sensor voltage greater than 4.5VDC
ER43 - Deck plate position sensor voltage noisy or changing in an incorrect direction
ER44 - Deck plate position sensor voltage range less than 2.0VDC
ER45 - Deck plate position sensor "closed" voltage greater than 2.5VDC
ER46 - Deck plate position sensor "opened" voltage less than 2.5VDC
ER51 - Header height resume sensor voltage less than 0.5VDC
ER52 - Header height resume sensor voltage greater than 4.5VDC
ER53 - Header height resume sensor voltage noisy or changing in an incorrect direction
ER54 - Header height resume sensor voltage range less than 2.0VDC
ER55 - Header height resume sensor "lowered" voltage greater than 2.5VDC
ER56 - Header height resume sensor "raised" voltage less than 2.5VDC
ER59 - Header height resume sensor has excessive hysteresis
ER71 - Left height sensor voltage less than 0.5VDC
ER72 - Left height position sensor voltage greater than 4.5VDC
ER73 - Left height position sensor voltage noisy or changing in an incorrect direction
ER74 - Left height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
ER75 - Left height position sensor "lowered" voltage greater than 2.5VDC
ER76 - Left height position sensor "raised" voltage less than 2.5VDC
ER77 - Left and right height sensor not stopping at same feeder house position
ER81 - Right height sensor voltage less than 0.5VDC
ER82 - Right height position sensor voltage greater than 4.5VDC
ER83 - Right height position sensor voltage noisy or changing in an incorrect direction
ER84 - Right height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
ER85 - Right height position sensor "lowered" voltage greater than 2.5VDC
ER86 - Right height position sensor "raised" voltage less than 2.5VDC
ER91 - Flex/belt center header height sensor voltage less than 0.5VDC
ER92 - Flex/belt center header height position sensor voltage greater than 4.5VDC
ER93 - Flex/belt center header height position sensor voltage noisy or changing in an incorrect direction
ER94 - Flex/belt center height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
ER95 - Flex/belt center header height position sensor "lowered" voltage greater than 2.5VDC
ER96 - Flex/belt center header height position sensor "raised" voltage less than 2.5VDC
CONTOURMASTER is a trademark of Deere & Company.
AG,OUO1035,1382 -19-05JAN00-1/1