5.
Turn the key switch to ignition position. Engine hydro charge pressure warning light (A), main gearcase pressure (B), engine oil pressure warning light (C) and parking brake indicator light (D) will come on if the park brake has been applied and the buzzer will sound one short pulse. If amber voltage light (E) comes on, this shows that battery voltage is low and combine may not start.
IMPORTANT:
To prevent starter damage, do not operate starter for more than 30 seconds at a time. If engine does not start, wait at least two minutes before trying again.
6.
Turn key switch clockwise to start. All lights on the warning display panel will come on. Release key when engine starts.
If temperature is below 40°F (5°C) it may be necessary to use ether aid (See ETHER AID in Operating the Engine section). After engine starts, let it run at low idle for five minutes to warm the oil. After the engine starts, all lights except the park brake must be out. If any other lights stay on, stop the engine and correct.
|
A-Hydro Charge Pressure
B-Main Gearcase Pressure
C-Engine Oil Pressure
D-Parking Brake
E-Amber Voltage Light
|