400 Hours or Yearly

H54746
 

A-Brake Fluid

B-Main Hydraulic/Hydrostatic Filter

C-Hydrostatic Charge Filter

 

1. Conveyor Auger Drive Bearings-Two fittings on 9650 combines.

2. Final Drive Outer Bearings (Both Sides)- When operating in mud and water, grease at 10 hours.

3. Brake Fluid Level (A). Look through cap. Add brake fluid to 6 mm (1/4 in.) from top. Do not let dirt get into brake fluid.

4. Main Hydraulic/Hydrostatic Filter (B). It is not necessary to drain the reservoir to change this filter.

Coat seal on new filter with oil . Hand tighten then tighten 1/2 turn more.

5. Straw Chopper Drive Countershaft Bearings.

6. Straw Chopper Drive Sheave.

7. Hydrostatic Charge Filter (C)- Coat seal on new filter with oil. Hand tighten then tighten 1/2 turn more.

HX,AG,SF7057 -19-22MAR99-1/1