High Pressure Switch
A high pressure condition can result from insufficient air flow across the condenser. When this happens, switch (A) (next to radiator) shuts off the compressor.
Shut off engine, remove key and set parking brake.
Clean condenser and filters.
Check for a broken fan belt.
Start engine and turn on air conditioning. If switch shuts off compressor again, see your John Deere dealer.
|