Lack Of Or Insufficient Cooling
|
Temperature slide lever in OFF position.
|
Select AIR CONDITIONING position.
|
|
Compressor belt off or broken.
|
Replace belt.
|
|
Compressor not functioning (if both the large and small hoses in the left-hand access panel are at the same temperature).
|
See your John Deere dealer.
|
|
High-pressure switch on - insufficient air flow across condenser.
|
Clean condenser. Check fan belt condition. Check engine fan speed belt position. Check rotary screen function. If this does not correct problem, see your John Deere dealer.
|
|
Low-pressure switch on - insufficient air flow across evaporator.
|
Clean filters. Check cab fan operation. If this does not correct problem, see your John Deere dealer.
|
|
Low-pressure switch on - low outside air temperature.
|
Move slide lever to warmer setting.
|
|
Low-pressure switch on - insufficient refrigerant level (bubbles in sight glass).
|
See your John Deere dealer.
|
|
Heater valve partially on - (with temperature lever in max. air conditioning, feel both heater hoses on right-hand side of cab. If both are warm, valve is open).
|
Adjust control rod through tray opening. Move lever to OFF. Loosen set screw in balljoint and when applying slight pressure down on rod, tighten balljoint.
|
Compressor clutch cycles excessively or compressor stays off up to 15 minutes.
|
Evaporator icing.
|
Adjust controls correctly. See OPERATOR'S STATION. Open louvers. Clean filters. Move lever to warmer setting.
|