ER02 - No header connected or invalid header type
-
ER03 - No corn head connected during deck plate calibration
-
ER21 - CONTOUR MASTER angle sensor voltage less than 0.5VDC
-
ER22 - CONTOUR MASTER angle sensor voltage greater than 4.5VDC
-
ER23 - CONTOUR MASTER angle sensor voltage noisy or changing in an incorrect direction
-
ER24 - CONTOUR MASTER angle voltage range less than 2.0VDC
-
ER25 - CONTOUR MASTER angle sensor "left" voltage greater than 2.5VDC
-
ER26 - CONTOUR MASTER angle sensor "right" voltage less than 2.5VDC
-
ER27 - CONTOUR MASTER angle sensor center voltage is not within 0.75VDC of mid-range
-
ER41 - Deck plate position sensor voltage less than 0.5VDC
-
ER42 - Deck plate position sensor voltage greater than 4.5VDC
-
ER43 - Deck plate position sensor voltage noisy or changing in an incorrect direction
-
ER44 - Deck plate position sensor voltage range less than 2.0VDC
-
ER45 - Deck plate position sensor "closed" voltage greater than 2.5VDC
-
ER46 - Deck plate position sensor "opened" voltage less than 2.5VDC
-
ER51 - Header height resume sensor voltage less than 0.5VDC
-
ER52 - Header height resume sensor voltage greater than 4.5VDC
-
ER53 - Header height resume sensor voltage noisy or changing in an incorrect direction
-
ER54 - Header height resume sensor voltage range less than 2.0VDC
-
ER55 - Header height resume sensor "lowered" voltage greater than 2.5VDC
-
ER56 - Header height resume sensor "raised" voltage less than 2.5VDC
|
-
ER59 - Header height resume sensor has excessive hysteresis
-
ER71 - Left height sensor voltage less than 0.5VDC
-
ER72 - Left height position sensor voltage greater than 4.5VDC
-
ER73 - Left height position sensor voltage noisy or changing in an incorrect direction
-
ER74 - Left height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
-
ER75 - Left height position sensor "lowered" voltage greater than 2.5VDC
-
ER76 - Left height position sensor "raised" voltage less than 2.5VDC
-
ER77 - Left and right height sensor not stopping at same feeder house position
-
ER81 - Right height sensor voltage less than 0.5VDC
-
ER82 - Right height position sensor voltage greater than 4.5VDC
-
ER83 - Right height position sensor voltage noisy or changing in an incorrect direction
-
ER84 - Right height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
-
ER85 - Right height position sensor "lowered" voltage greater than 2.5VDC
-
ER86 - Right height position sensor "raised" voltage less than 2.5VDC
-
ER91 - Flex/belt center header height sensor voltage less than 0.5VDC
-
ER92 - Flex/belt center header height position sensor voltage greater than 4.5VDC
-
ER93 - Flex/belt center header height position sensor voltage noisy or changing in an incorrect direction
-
ER94 - Flex/belt center height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
-
ER95 - Flex/belt center header height position sensor "lowered" voltage greater than 2.5VDC
-
ER96 - Flex/belt center header height position sensor "raised" voltage less than 2.5VDC
|