Recording

The recording screen shows recording data status.

To start recording data, ALL of the following must occur:

1. Separator engaged.
2. Header engaged.
3. Engine at high throttle position.
4. Header lowered (see Setup section).

To stop recording, ONE of the following must occur:

1. Header raised for more than selected time delay, which is set on Record Stop Delay or raised past Record Stop Height.
2. Header disengaged.
3. Button F pressed (to manually stop recording data).

ZX018551

OUO1035,00000ED -19-15NOV01-1/2


Recording can be manually stopped and restarted without raising the header or shutting off the separator (for example, when approaching areas such as headlands, end rows already harvested, waterways, etc., for which recording data is not desired).

NOTE: When recording has stopped, the word FIELD (A) will appear which indicates that the values are field averages for yield dry, yield wet and moisture.

To manually stop recording Press F. Display will change to RECORDING IS: OFF, and black arrow will toggle to START.

To resume recording press F or push header lower button on combine multi-function control handle to start recording data (a slight touch to the header lower button will start recording data). Display will change to RECORDING IS: ON, and black arrow will toggle to STOP.


A-Field

ZX018552

OUO1035,00000ED -19-15NOV01-2/2