Install and Reprogram GREENSTAR System from Field Documentation or Parallel Tracking to Yield Mapping

When a GREENSTAR system is programmed for field documentation or parallel tracking and is moved to another machine to be used for Yield Mapping, the system must be reprogrammed.

The following procedures show the basic connections and programming steps needed to prepare the system to operate in Yield Mapping mode. The mobile processor, display, and position receiver must be reprogrammed to operate in the Yield Mapping mode.

For up to date mapping software go to www.StellarSupport.com.

NOTE: Yield Mapping does not require a keycard to operate however, a Keycard must be in the mobile processor in order for the system to be reprogrammed from either parallel tracking or field documentation. All Keycards have yield mapping program installed on them.

1. Disconnect main wiring harness connector from the position receiver connector and remove position receiver from machine.

OUO6075,00022CA -19-31JUL02-1/13


2. Remove cap screws (A) and display assembly.

3. Disconnect gray (B) and black (C) wiring harness connectors.

4. Install position receiver onto machine and connect machine wiring harness to position receiver.

5. Attach display to bracket with previously removed hardware.

6. Attach gray connector to mobile processor connector and black connector to display connector.


A-Cap Screws
B-Gray Mobile Processor Connector
C-Black Display Connector

H64503

OUO6075,00022CA -19-31JUL02-2/13


7. Install Keycard (A) into top slot of mobile processor.

8. Turn ignition key to RUN position.

9. Press continue to cancel the following warning messages.

  • KeyCard Warning
  • Setup Data Missing
  • Data Network Error


A-KeyCard

PC6433

OUO6075,00022CA -19-31JUL02-3/13


NOTE: After installing the Keycard the following warning screen may appear and the automatic software load may start. Press continue to automatically reprogram the system from parallel tracking/field documentation to yield mapping.

10. Press continue to automatically reprogram the system. This should complete the reprogramming.

H70462

OUO6075,00022CA -19-31JUL02-4/13


NOTE: After pressing continue the system will check the version of software on the mobile processor and the moisture sensor. If the software on the Keycard is newer then on the components a warning screen will be displayed promoting the operator to update the software. Press continue on this screen to automatically update the software.

H70463

OUO6075,00022CA -19-31JUL02-5/13


NOTE: Use the following steps if the automatic software load does not occur.

11. Press SETUP button to access Setup screen.

ZX026754

OUO6075,00022CA -19-31JUL02-6/13


12. Press button next to KeyCard.

ZX026757

OUO6075,00022CA -19-31JUL02-7/13


13. Press button next to Yield Mapping on the SETUP - Products screen.

14. Press button next to Yield Mapping version.

ZX026766

OUO6075,00022CA -19-31JUL02-8/13


15. Press button next to Continue to update software.

ZX026765

OUO6075,00022CA -19-31JUL02-9/13


16. Program mode has started. Follow directions on screen:

Do Not Remove Power

ZX026767

OUO6075,00022CA -19-31JUL02-10/13


17. Programming is continuing. Follow directions on screen:

Do Not Remove Power

18. Programming has begun. Follow directions on screen:

Do Not Remove Power

ZX026768

OUO6075,00022CA -19-31JUL02-11/13


19. Wait until WARNING PROGRAMMING screen appears and follow directions on screen:

Do Not Remove PC Card

Do Not Remove Power

ZX027481

OUO6075,00022CA -19-31JUL02-12/13


20. When programming is complete, RUN-Yield Map - Page 1 screen will appear.

21. Press RUN button.

22. Remove the KeyCard from the mobile processor and insert yield mapping data card.

ZX018551

OUO6075,00022CA -19-31JUL02-13/13