NOTE:
See Adjusting Auger Height and Adjusting Auger Fore/Aft sections for procedures.
If step 7 causes the auger to interfere with floor stripper before clearance position is reached, adjust auger forward until interference is eliminated.
Rotate Auger frequently
during adjusting procedures.
Adjust auger equally.
Do not adjust one side completely to recommended clearance. Adjust auger ends equally to recommended clearance.
7.
Using the height and fore/aft adjustment procedures to position the auger flighting (A) 11 mm (7/16 in.) clearance to floor (B) and 11 mm (7/16 in.) to rear stripper (C).
NOTE:
Center auger finger clearance from floor to finger, 16 mm (5/8 in.), see Adjusting Center Auger Finger Timing section for procedures.
8.
Set center auger finger timing.
9.
Adjust strippers (see Adjusting Rear Stripper and Adjusting Floor Stripper sections for procedures).
10.
Adjust auger drive chain tension (see Adjust Auger Chain section for procedures).
|