-
ER01 Feeder house calibration must be done before header calibration procedure
-
ER02 No header connected or invalid header type
-
ER03 No corn head connected during deck plate calibration
-
ER11 Cutterbar flex pressure sensor less than 0.5VDC
-
ER21 - CONTOUR MASTER angle sensor less than 0.5VDC
-
ER22 - CONTOUR MASTER angle sensor greater than 4.5VDC
-
ER23 - CONTOUR MASTER angle sensor noisy or changing in an incorrect direction
-
ER24 - CONTOUR MASTER angle less than 2.0VDC
-
ER25 - CONTOUR MASTER angle sensor "left" greater than 2.5VDC
-
ER26 - CONTOUR MASTER angle sensor "right" less than 2.5VDC
-
ER27 - CONTOUR MASTER angle sensor center is not within 0.75VDC of mid-range
-
ER39 Lift cylinder pressure sensor less than 1.0VDC (3000 kPa; 30 bar; 435 psi)
-
ER41 Deck plate position sensor less than 0.5VDC
-
ER42 Deck plate position sensor greater than 4.5VDC
-
ER43 Deck plate position sensor noisy or changing in an incorrect direction
-
ER44 Deck plate position sensor less than 2.0VDC
-
ER45 Deck plate position sensor "closed" greater than 2.5VDC
-
ER46 Deck plate position sensor "opened" less than 2.5VDC
-
ER51 Header height resume sensor less than 0.5 V
-
ER52 Header height resume sensor greater than 4.5VDC
-
ER53 Header height resume sensor noisy or changing in an incorrect direction
-
ER54 Header height resume sensor less than 2.0VDC
|
-
ER55 Header height resume sensor "lowered" greater than 2.5VDC (3.0VDC on corn head)
-
ER56 Header height resume sensor "raised" less than 2.5VDC (3.0VDC on corn head)
-
ER59 Header height resume sensor has excessive hysteresis
-
ER61 Header raise valve deadband not consistent within 80mA
1
-
ER63 Header raise valve deadband greater than 1200mA
1
-
ER64 Header raise valve deadband less than 800mA
1
-
ER66 Header lower valve deadband not consistent within 80mA
1
-
ER68 Header lower valve deadband greater than 1200mA
1
-
ER69 Header lower valve deadband less than 800mA
1
-
ER71 Left height sensor less than 0.5VDC
-
ER72 Left height position sensor greater than 4.5VDC
-
ER73 Left height position sensor noisy or changing in an incorrect direction
-
ER74 Left height position sensor less than 2.0VDC (1.5VDC for flex platforms)
-
ER75 Left height position sensor "lowered" greater than 2.5VDC
-
ER76 Left height position sensor "raised" less than 2.5VDC
-
ER77 Left and right height sensor not stopping at same feeder house position
-
ER81 Right height sensor less than 0.5VDC
-
ER82 Right height position sensor greater than 4.5VDC
-
ER83 Right height position sensor noisy or changing in an incorrect direction
-
ER84 Right height position sensor less than 2.0VDC (1.5VDC for flex platforms)
-
ER85 Right height position sensor "lowered" greater than 2.5VDC
|