IMPORTANT:
Change oil every 100 hours if fuel is more than 0.5 % sulfur.
Fill crankcase with seasonal viscosity grade oil or TORQ-GARD SUPREME
(250 hours change interval). If using PLUS-50
oil and a John Deere filter, service interval can be extended by 50 percent. Example: 250 Hours extends to 375 Hours.
Do not operate engine with oil level below low mark on dipstick.
|
1.
Engine Crank Case Filter. Remove and replace filter (A) and drain oil at (B). Install and tighten cap to specification.
Specification
|
Top Load Filter Cap
-Torque
|
40 N·m
|
(30 lb-ft)
|
2.
Remove dipstick (C) to fill and check.
|