Every 250 Hours

H78694
 

A-Filter

B-Drain

C-Dipstick

 

IMPORTANT: Change oil every 100 hours if fuel is more than 0.5 % sulfur.

Fill crankcase with seasonal viscosity grade oil or TORQ-GARD SUPREME ™ (250 hours change interval). If using PLUS-50 ™ oil and a John Deere filter, service interval can be extended by 50 percent. Example: 250 Hours extends to 375 Hours.

Do not operate engine with oil level below low mark on dipstick.

1. Engine Crank Case Filter. Remove and replace filter (A) and drain oil at (B). Install and tighten cap to specification.

Specification

Top Load Filter Cap -Torque 40 N·m (30 lb-ft)
Fill crankcase oil and check at (C).

TORQ-GARD SUPREME is a trademark of Deere & Company
PLUS-50 is a trademark of Deere & Company

OUO6075,0003183 -19-21OCT03-1/1