Calibration Service Codes

  • ER01 Feeder house calibration must be done before header calibration procedure
  • ER02 No header connected or invalid header type
  • ER03 No corn head connected during deck plate calibration
  • ER11 Cutterbar flex pressure sensor less than 0.5VDC
  • ER21 - CONTOUR MASTER angle sensor less than 0.5VDC
  • ER22 - CONTOUR MASTER angle sensor greater than 4.5VDC
  • ER23 - CONTOUR MASTER angle sensor noisy or changing in an incorrect direction
  • ER24 - CONTOUR MASTER angle less than 2.0VDC
  • ER25 - CONTOUR MASTER angle sensor "left" greater than 2.5VDC
  • ER26 - CONTOUR MASTER angle sensor "right" less than 2.5VDC
  • ER27 - CONTOUR MASTER angle sensor center is not within 0.75VDC of mid-range
  • ER39 Lift cylinder pressure sensor less than 1.0VDC (3000 kPa; 30 bar; 435 psi)
  • ER41 Deck plate position sensor less than 0.5VDC
  • ER42 Deck plate position sensor greater than 4.5VDC
  • ER43 Deck plate position sensor noisy or changing in an incorrect direction
  • ER44 Deck plate position sensor less than 2.0VDC
  • ER45 Deck plate position sensor "closed" greater than 2.5VDC
  • ER46 Deck plate position sensor "opened" less than 2.5VDC
  • ER51 Header height resume sensor less than 0.5 V
  • ER52 Header height resume sensor greater than 4.5VDC
  • ER53 Header height resume sensor noisy or changing in an incorrect direction
  • ER54 Header height resume sensor less than 2.0VDC
  • ER55 Header height resume sensor "lowered" greater than 2.5VDC (3.0VDC on corn head)
  • ER56 Header height resume sensor "raised" less than 2.5VDC (3.0VDC on corn head)
  • ER59 Header height resume sensor has excessive hysteresis
  • ER61 Header raise valve deadband not consistent within 80mA 1
  • ER63 Header raise valve deadband greater than 1200mA 1
  • ER64 Header raise valve deadband less than 800mA 1
  • ER66 Header lower valve deadband not consistent within 80mA 1
  • ER68 Header lower valve deadband greater than 1200mA 1
  • ER69 Header lower valve deadband less than 800mA 1
  • ER71 Left height sensor less than 0.5VDC
  • ER72 Left height position sensor greater than 4.5VDC
  • ER73 Left height position sensor noisy or changing in an incorrect direction
  • ER74 Left height position sensor less than 2.0VDC (1.5VDC for flex platforms)
  • ER75 Left height position sensor "lowered" greater than 2.5VDC
  • ER76 Left height position sensor "raised" less than 2.5VDC
  • ER77 Left and right height sensor not stopping at same feeder house position
  • ER81 Right height sensor less than 0.5VDC
  • ER82 Right height position sensor greater than 4.5VDC
  • ER83 Right height position sensor noisy or changing in an incorrect direction
  • ER84 Right height position sensor less than 2.0VDC (1.5VDC for flex platforms)
  • ER85 Right height position sensor "lowered" greater than 2.5VDC

1If this service code appears then replace the valve.

OUO6075,00026D6 -19-12FEB03-1/2


  • ER86 Right height position sensor "raised" less than 2.5VDC
  • ER91 - Flex/belt center header height sensor less than 0.5VDC
  • ER92 - Flex/belt center header height position sensor greater than 4.5VDC
  • ER93 - Flex/belt center header height position sensor noisy or changing in an incorrect direction
  • ER94 - Flex/belt center height position sensor less than 2.0VDC (1.5VDC for flex platforms)
  • ER95 - Flex/belt center header height position sensor "lowered" greater than 2.5VDC
  • ER96 - Flex/belt center header height position sensor "raised" less than 2.5VDC