Diagnostic Trouble Code Priorities

Diagnostic Trouble Code Priorities

Each Diagnostic Trouble Code (DTC) has a priority. The priority of the DTC is indicated in the way the DTC is displayed to the operator:

  • Priority 1 - The Cornerpost Display will stop normal function and the DTC will be displayed. This indicates a problem that requires the combine be stopped, the engine turned off immediately and the problem corrected. The Cornerpost Display will show the DTC until the problem is resolved.
  • Priority 2 - The Cornerpost Display Diagnostic Indicator comes on. This indicates a problem that should be checked immediately.
  • Priority 3 - DTC's will be stored, but it is not indicated to the operator.

OUO6075,0003174 -19-21OCT03-1/13


NOTE: Some codes may be activated that are not addressed in this book. These codes are of low severity. Contact your John Deere dealer at your convenience.

A00 - Engine Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
A00 94 1 1 Fuel pressure too low - less than 300 kPa / 44 PSI.
A00 94 3 2 Fuel Pressure Sensor (cc# 135) voltage out of range high.
A00 94 4 2 Fuel Pressure Sensor (cc# 135) voltage out of range low.
A00 94 16 2 Fuel pressure is too high - above 820 kPa (119 PSI) at 900 RPM or above 890 kPa (129 PSI) at 2100 RPM.
A00 94 18 2 Fuel pressure too low - less than 400 kPa / 58 PSI.
A00 97 3 2 Water in Fuel Sensor (cc# 136) voltage out of range high.
A00 97 4 2 Water in Fuel Sensor (cc# 136) voltage out of range low.
A00 97 31 2 Water is detected in fuel. Drain water separator bowl.
A00 97 31 1 Water is detected in fuel. Drain water separator bowl.
A00 100 1 1 Oil Pressure Sensor is open after engine RPM is above cranking speed.
A00 100 4 2 Oil Pressure Sensor is closed when engine is not running.
A00 105 3 2 Engine Manifold Air Temperature Sensor voltage is out of range high. The device or wiring is faulty.
A00 105 4 2 Engine Manifold Air Temperature Sensor voltage is out of range low. The device or wiring is faulty.
A00 105 16 2 Engine manifold air temperature above 88°C / 190°F (moderately severe level). Maximum power level is derated. Power boost is disabled.
A00 107   2 Air Filter Restricted Switch indicates a plugged air filter.
A00 110   1 Engine coolant temperature above 113°C / 235°F (most severe level). Maximum power level is derated. Power boost is disabled.
A00 110 3 2 Engine Coolant Temperature Sensor voltage is out of range high. The device or wiring is faulty.
A00 110 4 2 Engine Coolant Temperature Sensor voltage is out of range low. The device or wiring is faulty.
A00 110 16 2 Engine coolant temperature above 108°C / 226°F. Maximum power level is derated. Power boost is disabled.
A00 158 17 2 Controller not powered down properly.
A00 174 3 2 Engine Fuel Temperature Sensor voltage is out of range high. The device or wiring is faulty.
A00 174 4 2 Engine Fuel Temperature Sensor voltage is out of range low. The device or wiring is faulty.
A00 611 3 2 The injector driver has detected a short to battery in the injector wiring.
A00 611 4 2 The injector driver has detected a short to ground in the injector wiring.
A00 620 3 2 Engine Control Unit internal 5 Volts DC Supply out of range or incorrect high.
A00 620 4 2 Engine Control Unit internal 5 Volts DC Supply out of range or incorrect low.

 

OUO6075,0003174 -19-21OCT03-2/13


A00 627 1 2 All injector currents are out of specification. The injector pull-incurrent is too low or the injector hold-in current is incorrect.
A00 636 2 2 Electrical noise detected on Pump Position Sensor + (cc# 172) and/or Pump Position Sensor - (cc# 173).
A00 636 8 2 Pump Position Sensor signal is missing.
A00 636 10 2 Pump Position Sensor signal has incorrect pulse pattern.
A00 637 2 2 Electrical noise detected on Engine Speed Sensor + (cc# 174) and/or Engine Speed Sensor - (cc# 175).
A00 637 7 2 Position relationship between Engine Speed Sensor and Pump Position Sensor not correct.
A00 637 8 2 Engine Speed Sensor signal is missing.
A00 637 10 2 Engine Speed Sensor signal has incorrect pulse pattern.
A00 651 5 2 The current to Injector #1 is less than expected.
A00 651 6 2 The current to Injector #1 increases too rapidly.
A00 652 5 2 The current to Injector #2 is less than expected.
A00 652 6 2 The current to Injector #2 increases too rapidly.
A00 653 5 2 The current to Injector #3 is less than expected.
A00 653 6 2 The current to Injector #3 increases too rapidly.
A00 654 5 2 The current to Injector #4 is less than expected.
A00 654 6 2 The current to Injector #4 increases too rapidly.
A00 655 5 2 The current to Injector #5 is less than expected.
A00 655 6 2 The current to Injector #5 increases too rapidly.
A00 656 5 2 The current to Injector #6 is less than expected.
A00 656 6 2 The current to Injector #6 increases too rapidly.
A00 1569 31 2 Engine protection - power derated due to other faults. This code occurs in conjunction with 105.16, 110.00, 110.03, 110.04, and 110.16.
A00 2000 13 1 Engine Control Unit security violation.

 

C00 - Armrest Control Unit Diagnostic Trouble Codes

C00 627 3 1 Delayed Power (cc# 006) voltage is above 16 VDC. High voltage situation must be resolved.
C00 628 12 1 Controller cannot exit boot block program. Disconnect Armrest Control Unit connectors X653 and X654. Reconnect connectors. Replace Armrest Control Unit if condition persists.
C00 630 11 1 Controller failed EEPROM test at power-up. Replace Armrest Control Unit if condition persists.
C00 1490 8 2 Backshaft speed unknown. Damage could occur to feeder house if direction is changed while feeder house is turning.
C00 1499 12 2 The separator engage fault detection circuit indicates a failure. This is an important disengagement override system. Replace the Armrest Control Unit if condition persists.
C00 1504 11 1 The Seat Switch has been closed continuously for 6 hours. The switch or the wiring harness is shorted. The header will not disengage when the operator has left the seat. This must be corrected.

 

OUO6075,0003174 -19-21OCT03-3/13


C03 - Cornerpost Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
C03 628 12 1 Controller cannot exit boot block program. Disconnect Cornerpost Control Unit connector X500. Reconnect connector. Replace Cornerpost Control Unit if condition persists.
C03 630 11 1 EEPROM failed test at power up. Replace Cornerpost Control Unit if condition persists.

 

E00 - Tailings Master Sensor Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
E00 628 12 2 Controller cannot exit boot block program. Turn Key Switch to the OFF position. Wait 30 seconds. Replace Master Tailings Sensor if condition persists.
E00 630 11 2 EEPROM failed test at power up. Replace the Master Tailings Sensor if condition persists.

 

OUO6075,0003174 -19-21OCT03-4/13


E01 - Header Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
E01 627 3 1 Controller supply voltage out of range high - greater than 16 VDC.
E01 628 12 1 Controller cannot exit boot block program. Disconnect Header Control Unit connector X205. Reconnect connector. Replace Header Control Unit if condition persists
E01 1079 3 2 Height Sensor Power (cc# 481) voltage is too high - greater than 5.25VDC. Height Sensor Power is used to power the Return To Cut Sensor, Reel Fore/Aft Position Sensor, Deck Plate Position Sensor, Right Header Height Sensor, Center Header Height Sensor and Left Header Height Sensor. The voltage regulator of the Header Control Unit is bad or there is a short in the wiring.
E01 1079 4 2 Height Sensor Power (cc# 481) voltage is too low - less than 4.75VDC. Height Sensor Power is used to power the Return To Cut Sensor, Reel Fore/Aft Position Sensor, Deck Plate Position Sensor, Right Header Height Sensor, Center Header Height Sensor and Left Header Height Sensor. The voltage regulator of the Header Control Unit is bad or there is a short in the wiring.
E01 1080 3 2 Height Sensor Power 2 (cc# 471) voltage is too high - greater than 5.25VDC. Height Sensor Power 2 is used to power the CONTOUR MASTER Angle Sensor and the Header Raise Pressure Sensor. The voltage regulator of the Header Control Unit is bad or there is a short in the wiring.
E01 1080 4 2 Height Sensor Power 2 (cc# 471) voltage is too low - less than 4.75VDC. Height Sensor Power 2 is used to power the CONTOUR MASTER Angle Sensor and the Header Raise Pressure Sensor. The voltage regulator of the Header Control Unit is bad or there is a short in the wiring.
E01 1515 13 2 Active Header Height Control system or CONTOUR MASTER system not calibrated for currently attached header. Perform the calibration procedure.
E01 1516 13 2 Header Float system not calibrated for currently attached header. Perform the calibration procedure.
E01 1517 4 2 Header Raise Pressure (cc# 706) voltage is too low - less than 0.25VDC.
E01 1519 11 2 Header raise valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the Header Raise Valve until the fault condition is removed.
E01 1520 11 2 Header lower valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the Header Lower Valve until the fault condition is removed.
E01 1521 11 2 Tilt left valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the CONTOUR MASTER Tilt Left Valve until the fault condition is removed.
E01 1522 11 2 Tilt right valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the CONTOUR MASTER Tilt Right Valve until the fault condition is removed.

 

OUO6075,0003174 -19-21OCT03-5/13


E01 1523 11 2 HYDRAFLEX diverter valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the HYDRAFLEX Diverter Valve until the fault condition is removed.
E01 1531 6 2 Reel speed increase driver detects an open, short, over voltage, over temperature condition. The Header Control Unit will not actuate the Reel Speed Actuator in the increase speed mode until the fault condition is removed
E01 1532 6 2 Reel speed decrease driver detects an open, short, over voltage, over temperature condition. The Header Control Unit will not actuate the Reel Speed Actuator in the decrease speed mode until the fault condition is removed
E01 1533 3 2 Height Resume Sensor (cc# 828) voltage is too high - greater than 4.5VDC. Faulty device or wiring.
E01 1533 4 2 Height Resume Sensor (cc# 828) voltage is too low - less than 0.5 VDC. Faulty device or wiring.
E01 1534 3 2 Left Header Height Sensor (cc# 412) voltage is too high - greater than 4.5 VDC. Faulty device or wiring.
E01 1534 4 2 Left Header Height Sensor (cc# 412) voltage is too low less than 0.5VDC. Faulty device or wiring.
E01 1535 3 2 Right Header Height Sensor (cc# 454) voltage is too high - greater than 4.5 VDC). Faulty device or wiring.
E01 1535 4 2 Right Header Height Sensor (cc# 454) voltage is too low - less than 0.5 VDC). Faulty device or wiring.
E01 1536 3 2 Center Header Height Sensor (cc# 414) voltage is too high - greater than 4.5 VDC or shorted pads of the DIAL-A-MATIC Sensor. Faulty device or wiring.
E01 1536 4 2 Center Header Height Sensor (cc# 414) voltage is too low - less than 0.5 VDC or no signal from DIAL-A-MATIC Sensor. Faulty device or wiring.
E01 1541 2 2 Reel speed unknown.
E01 298618 7 2 Reel raise/lower or fore/aft resume system has malfunctioned.
E01 298621 7 2 HYDRAFLEX system has malfunctioned.

 

OUO6075,0003174 -19-21OCT03-6/13


E02 - Right Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
E02 627 3 1 Electronic Power (cc# 021) voltage is too high - greater than 16VDC.
E02 628 12 1 Controller cannot exit boot block program. Turn Key Switch to the OFF position. Wait for 30 seconds. Replace Right Control Unit if condition persists.
E02 630 11 2 EEPROM failed test on power up. Replace the Right Control Unit if condition persists.
E02 639 19 2 CAN Bus messages are not being transmitted or received correctly. Possible effects are none, slow response, or machine down.
E02 1508 3 2 Hydraulic Oil Temperature Sensor (cc# 775) voltage is too high - greater than 4.97 VDC. The device or wiring is faulty.
E02 1508 4 2 Hydraulic Oil Temperature Sensor (cc# 775) voltage is too low - less than 0.29 VDC. The device or wiring is faulty.
E02 1509 3 2 Main Gear Case Oil Temperature Sensor (cc# 774) voltage is too high -greater than 4.97 VDC. The device or wiring is faulty.
E02 1509 4 2 Main Gear Case Oil Temperature Sensor (cc# 774) voltage is too low -less than 0.29 VDC. The device or wiring is faulty.

 

OUO6075,0003174 -19-21OCT03-7/13


E03 - Left Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
E03 627 3 1 Electronic Power (cc# 021) voltage is too high - greater than 15.5 VDC.
E03 628 12 1 Controller cannot exit boot block program. Disconnect Left Control Unit connector X213. Reconnect connector. Replace Left Control Unit if condition persists.
E03 876 11 2 CLIMATRAK compressor driver detects an open, short, over voltage, or over temperature condition.
E03 200132 11 1 Left brake light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode.
E03 200133 11 1 Right brake light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode.
E03 200134 11 1 Left marker light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode.
E03 200135 11 1 Right marker light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode.
E03 200137 11 2 Feeder house reverser driver detects an open, short, over voltage, or over temperature condition.
E03 200140 3 2 12VDC detected on Power Ground (cc# 010) of Control Relay Board. Indicates problem with ground connections.
E03 200141 4 2 12VDC not detected on Unswitched Electronic Power (cc# 022) of Control Relay Board. Indicates problem with Unswitched Electronic Power connection, wiring or Fuse F20 of the Engine Compartment Relay Panel.
E03 200142 4 2 12VDC not detected on Light Power (cc# 014) of Control Relay Board. Indicates problem with Light Power connection, wiring or Fuse F18 of the Engine Compartment Relay Panel.
E03 200143 4 2 12VDC not detected on Control Power (cc# 016) of Control Relay Board. Indicates problem with Control Power connection, wiring, Fuse F8 or Relay K4 of the Engine Compartment Relay Panel.
E03 200144 4 2 12VDC not detected on Light Power 2 (cc# 046) of Control Relay Board. Indicates problem with Light Power 2 connection, wiring or Fuse F5 of the Engine Compartment Relay Panel.
E03 200145 4 2 12VDC not detected on Light Power 3 (cc# 047) of Control Relay Board. Indicates problem with Light Power 3 connection, wiring or Fuse F3 of the Engine Compartment Relay Panel.
E03 200147 4 2 12VDC not detected on Fan Speed Adjust Power (cc# 051) of Control Relay Board. Indicates problem with Fan Speed Adjust Power connection, wiring or Fuse F11 or Relay K5 of the Engine Compartment Relay Panel.
E03 200148 4 2 12VDC not detected on Light Power 5 (cc# 049) of Control Relay Board. Indicates problem with Light Power 5 connection, wiring or Fuse F9 of the Engine Compartment Relay Panel.
E03 200149 11 2 Indicates a problem in the serial communication link between the Left Control Unit and the Control Relay Board.

 

OUO6075,0003174 -19-21OCT03-8/13


E04 - Left Control Unit 2 Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
E04 627 03 1 Delayed Power (cc# 006) voltage is too high - greater than 15.5 VDC.
E04 628 12 2 Controller cannot exit boot block program. Disconnect Left Control Unit 2 connectors X314 and X315. Reconnect connectors. Replace Armrest Control Unit if condition persists.
E04 1388 03 2 Rotor Drive Pressure (cc# 723) voltage is too high - greater than 4.98 VDC.
E04 1388 04 2 Rotor Drive Pressure (cc# 723) voltage is too low - less than 0.20 VDC.
E04 1503 09 2 CAN Bus message(s) missing from Armrest Control Unit

 

WARNING Messages and Fault Codes Displayed on GREENSTAR ™ Display

HARVEST DOC and HARVEST MONITOR Warning messages:

Messages generated by a problem controller(s) are sent to the GREENSTAR Display over the CAN Bus network.

A WARNING message is displayed on the GREENSTAR Display as a full page message. Cancelling the WARNING message by pressing the button next to the word CANCEL will cause the message to disappear.

CAUTION messages located in section "G" of the GREENSTAR Display will be displayed following the canceling of the WARNING message. When the problem is fixed or no longer exists the CAUTION message in section "G" will no longer be displayed.

HARVEST DOC and HARVEST MONITOR Internal Fault Codes:

Fault Codes can be viewed by pressing the INFO button on the GREENSTAR Display. Then pressing the button next to the entry GREENSTAR Display followed by pressing the button next to the words Recent Problems . The codes will be displayed on this page with a short description following the code. To clear these Fault Code(s), press the button next to the words Fault Codes .

GREENSTAR is a trademark of Deere & Company

OUO6075,0003174 -19-21OCT03-9/13


GREENSTAR Display Warning Messages and Fault Codes

Control Unit SPN FMI WARNING Messages / Fault Codes Pri. Description
0x80     200/20   CAN Bus Problem
The indicated device(s) are no longer communicating with the GREENSTAR Display.
Check the indicated device(s) and CAN Bus wiring.
0x80     201/21   CAN Bus Problem
Two Devices are requesting the same Run Page section.
Perform Run Page Layout to correct the conflict.
0x80     210/30   CAN Bus Problem
Too many devices are attempting to communicate with the GREENSTAR Display.
Remove 1 or more devices.
0x80     211/31   CAN Bus Problem
CAN Bus communications overload.
Reset the display or turn the power off and then back on.
0x80     213/33   Internal Error.
A failure has been detected in the GREENSTAR Display's internal memory.
Replace GREENSTAR Display if problem persists
0x80     220/40   Parallel Tracking Problem
Parallel tracking is not receiving data from the GPS receiver.CheckGPS receiver connectionWiring harness
0x80     221/41   Parallel Tracking Problem
The GPS Receiver is not able to acquire a differential correction signal.
0x80     224/44   Parallel Tracking Problem
No Parallel Tracking Key on KeyCard or no KeyCard present.
Install KeyCard with Parallel Tracking key in Mobile Processor.
0x80     225/45   Parallel Tracking Problem
The GPS receiver must be set to report at the 5 Hz. rate.Confirm:STARFIRE Receiver report rateLicense Level SFire2
0x80     226/46   Parallel Tracking Problem
The GPS receiver has no GPS signal.
0x80     227/50   Automatic Steering Problem.
No communication with the steering controller.
0x80     230/47   Display Address Change.
You are about to change the address of the GREENSTAR Display.
Selection of the wrong address will cause loss of communication with implements.
0x80     231/52   CAN Bus Problem
Multiple primary GREENSTAR Displays detected on the bus.
Only one primary display is allowed on the bus.

 

OUO6075,0003174 -19-21OCT03-10/13


Control Unit SPN FMI WARNING Messages / Fault Codes Pri. Description
0x80     232/52   CAN Bus Problem
No primary GREENSTAR Display detected.
All systems require a primary display.
0x80     233/22   Language Selection Problem.
The following device(s) do not support the selected language.
They will continue to use the previously selected language.
0x80     234/53   CAN Bus Problem
This display is on the CCD bus.
It must be the primary address. Switch your display addresses.
0x80     235/54   CAN Bus Problem
The auto-detected CAN layer differs from the current layer selected.
Please change the selected layer.
0x80     236/55   AutoTrac Problem
The operator is responsible for the machine path.
Turn AutoTrac OFF before entering roadways.
0x80     /60   Flash Erase Failed.
GREENSTAR Display having problems erasing contour paths from memory
Replace GREENSTAR Display if problem persists
0x80     /61   Contour Write Error -
GREENSTAR Display having problems writing contour paths to memory
Replace GREENSTAR Display if problem persists
0x80     /110   Check Wiring (CAN Bus)
Wiring problem with Harness
0x80     /111   Check Wiring (CCD)
CAN to CCD Queue Overflow
0x80     /113   Incompatible mon/cntrl.
Check for compatible controllers on CAN Bus
0x80     /120   NO GPS
GPS receiver unable to communicate with satellites
Tracking disabled
0x80     /121   No Differential GPS
The GPS Receiver is not able to acquire a differential correction signal.
Tracking disabled
0x80     /122   WAAS in use.
Tracking inaccurate
0x80     /123   SF1 in use.
Tracking inaccurate
0x80     /124   GPS Updates are 1 Hz.
Tracking inaccurate
0x80     /126   AutoTrac disabled.
Using a version of Mobile Processor Application Code that is not using secure CAN.
Occurs with versions released before July 2002.

 

OUO6075,0003174 -19-21OCT03-11/13


Moisture Sensor Warning Messages

Control Unit SPN FMI Warning Messages Pri. Description
0XD3     1   Plunger initialization failure - Plunger could not be initialized.
Moisture disabled.
Call dealer for service.
0XD3     2   Actuator shorted - moisture disabled.
Call dealer for service.
0XD3     3   Relay failure - moisture disabled. Call dealer for service.
0XD3     4   Motor failure - moisture disabled.
Call dealer for service.
0XD3     6   Low voltage - Electronic Power (cc# 21) voltage at Moisture Sensor is too low.
Please check wiring cc# 21 and cc# 20
0XD3     7   Low voltage - Delayed power (cc# 6) voltage at Moisture Sensor is too low.
Data will be lost when vehicle turned off.
Moisture disabled.
Call dealer for service.
0XD3     8   Low voltage - Mass Flow Sensor power (cc# 971) voltage is too low.
Mass Flow disabled.
Call dealer for service.
0XD3     9   High voltage - Mass Flow Sensor power (cc# 971) voltage Is too high.
Mass Flow disabled.
Call dealer for service.
0XD3     10   Low voltage - Analog voltage is too low. x Volts
Moisture disabled.
Call dealer for service.
0XD3     11   High voltage - Analog voltage is too high. X volts
Moisture disabled.
Call dealer for service.
0XD3     12   You are about to delete a Farm Name and all Field Names and Field totals associated with the selected Farm.
0XD3     13   You are about to delete a Field Name and all Field Totals for the selected Field.
0XD3     14   Moisture Curve Modify - You are about to modify a moisture curve.
0XD3     15   Moisture Curve Invalid - The digits entered are not valid.
Check the data and try again.
0XD3     16   Moisture Curve Conflict - Moisture disabled.
Verify Curve 1 and Curve 2 data from the Info Diagnostic page for the currently selected crop.
0XD3     18   Mass Flow out of range - Mass Flow Sensor Signal (cc# 972) voltage is too low.
Mass Flow disabled.
Please check wiring CC970, CC971, and CC972. Call dealer for service.
0XD3     19   Mass Flow out of range - Mass Flow Sensor Signal (cc# 972) voltage is too high.
Please check wiring CC970, CC971, and CC972.
Mass Flow disabled.
Call dealer for service.

 

OUO6075,0003174 -19-21OCT03-12/13


Control Unit SPN FMI Warning Messages Pri. Description
0XD3     20   Offset out of range - The calculated offset is out of range.
It must be >-10.1 and < +10.1
Offset not modified.
0XD3     21   Mass Flow calibration is running. Cannot change crop until calibration is stopped.
0XD3     22   You are about to clear the Field Totals for the selected Field.
0XD3     23   You are about to clear all Crop Totals for the selected crop.
      24   You are about to clear all Field and Crop Totals.
0XD3     25   The selected crop is: CORN
Empty grain tank before proceeding.
0XD3     26   Yield Estimator
Step X
Harvest at:
Y mph/kph
0XD3     28   Combine in transport mode. Check farm, field and crop selection.
0XD3     29   The mapping processor is not working. moisture and Mass flow will only be available. (No Mapping)
0XD3     30   You are about to clear flash records. (except the hardware records)
0XD3     32   Motor Stalled - The motor has stalled during initialization.
Clean GREENSTAR Moisture Sensor.
Moisture will be disabled until initialization is successful.

 

OUO6075,0003174 -19-21OCT03-13/13