| Control Unit |
Warning Messages / Fault Codes |
Description |
| 0x80 |
200/20 |
CAN Bus Problem The indicated device(s) are no longer communicating with the GREENSTAR Display. Check the indicated device(s) and CAN Bus wiring. |
| 0x80 |
201/21 |
CAN Bus Problem Two Devices are requesting the same Run Page section. Perform Run Page Layout to correct the conflict. |
| 0x80 |
210/30 |
CAN Bus Problem Too many devices are attempting to communicate with the GREENSTAR Display. Remove 1 or more devices. |
| 0x80 |
211/31 |
CAN Bus Problem CAN Bus communications overload. Reset the display or turn the power off and then back on. |
| 0x80 |
213/33 |
Internal Error. A failure has been detected in the GREENSTAR Display's internal memory. Replace GREENSTAR Display if problem persists |
| 0x80 |
220/40 |
Parallel Tracking Problem Parallel tracking is not receiving data from the GPS receiver.Check- GPS receiver connection
- Wiring harness
|
| 0x80 |
221/41 |
Parallel Tracking Problem The GPS Receiver is not able to acquire a differential correction signal. |
| 0x80 |
224/44 |
Parallel Tracking Problem No Parallel Tracking Key on KeyCard or no KeyCard present. Install KeyCard with Parallel Tracking key in Mobile Processor. |
| 0x80 |
225/45 |
Parallel Tracking Problem The GPS receiver must be set to report at the 5 Hz. rate.Confirm:- STARFIRE Receiver report rate
- License Level SFire2
|
| 0x80 |
226/46 |
Parallel Tracking Problem The GPS receiver has no GPS signal. |
| 0x80 |
227/50 |
Automatic Steering Problem. No communication with the steering controller. |
| 0x80 |
230/47 |
Display Address Change. You are about to change the address of the GREENSTAR Display. Selection of the wrong address will cause loss of communication with implements. |
| 0x80 |
231/52 |
CAN Bus Problem Multiple primary GREENSTAR Displays detected on the bus. Only one primary display is allowed on the bus. |
| Control Unit |
Warning Messages / Fault Codes |
Description |
| 0x80 |
232/49 |
CAN Bus Problem No primary GREENSTAR Display detected. All systems require a primary display. |
| 0x80 |
233/22 |
Language Selection Problem. The following device(s) do not support the selected language. They will continue to use the previously selected language. |
| 0x80 |
235/54 |
CAN Bus Problem The auto-detected CAN layer differs from the current layer selected. Please change the selected layer. |
| 0x80 |
236/55 |
AutoTrac Problem The operator is responsible for the machine path. Turn AutoTrac OFF before entering roadways. |
| 0x80 |
/60 |
Flash Erase Failed. GREENSTAR Display having problems erasing contour paths from memory Replace GREENSTAR Display if problem persists |
| 0x80 |
/61 |
Contour Write Error - GREENSTAR Display having problems writing contour paths to memory Replace GREENSTAR Display if problem persists |
| 0x80 |
/110 |
Check Wiring (CAN Bus) Wiring problem with Harness |
| 0x80 |
/113 |
Incompatible mon/cntrl. Check for compatible controllers on CAN Bus |
| 0x80 |
/120 |
NO GPS GPS receiver unable to communicate with satellites Tracking disabled |
| 0x80 |
/121 |
No Differential GPS The GPS Receiver is not able to acquire a differential correction signal. Tracking disabled |
| 0x80 |
/122 |
WAAS in use. Tracking inaccurate |
| 0x80 |
/123 |
SF1 in use. Tracking inaccurate |
| 0x80 |
/124 |
GPS Updates are 1 Hz. Tracking inaccurate |
| 0x80 |
/126 |
AutoTrac disabled. Using a version of Mobile Processor Application Code that is not using secure CAN. Occurs with versions released before July 2002. |
| Control Unit |
SPN |
FMI |
Warning Messages |
Description |
| 0XD3 |
3509 |
18 |
|
Low voltage. Delayed power voltage at Moisture Sensor is too low. Data will be lost when vehicle turned off. Moisture disabled. Call dealer for service. |
| 0XD3 |
3510 |
16 |
|
High voltage - Mass Flow Sensor power (cc# 971) voltage is too high. Mass Flow disabled. Call dealer for service. |
| 0XD3 |
3510 |
18 |
|
Low voltage - Mass Flow Sensor power (cc# 971) voltage is too low. Mass Flow disabled. Call dealer for service. |
| 0XD3 |
3511 |
16 |
|
High voltage - Analog voltage is too high. Moisture disabled. Call dealer for service. |
| 0XD3 |
3511 |
18 |
|
Low voltage. Analog voltage is too low. Moisture disabled. Call dealer for service. |
| 0XD3 |
522878 |
16 |
|
Over temperature - Measured temperature is out of range - Moisture sensor will not operate when temperature reaches over 85 degrees centigrade. |
| 0XD3 |
522976 |
14 |
|
Indicates loss of communication with Mobile Processor. System is operating as Harvest Monitor. |
| 0XD3 |
522979 |
16 |
09 |
High voltage - Mass Flow Sensor power (cc# 971) voltage is too high. Mass Flow disabled. Call dealer for service. |
| 0XD3 |
522979 |
18 |
08 |
Low voltage - Mass Flow Sensor power (cc# 971) voltage is too low. Mass Flow disabled. Call dealer for service. |
| 0XD3 |
523105 |
12 |
04 |
Motor failure. Moisture disabled. Indicates the moisture sensor is not functioning due to motor failure. |
| 0XD3 |
523105 |
14 |
32 |
Motor Stalled - The motor has stalled during initialization. Clean GREENSTAR Moisture Sensor. Moisture will be disabled until initialization is successful. |
| 0XD3 |
523106 |
11 |
3 |
Relay failure. Moisture disabled. Check relays on Moisture actuator. |
| 0XD3 |
523107 |
06 |
2 |
Actuator shorted - moisture disabled. Call dealer for service. |
| 0XD3 |
523107 |
07 |
1 |
Plunger initialization failure. Plunger could not be initialized. Moisture disabled. Indicates that the Moisture Sensor Plunger is not retracting or extending |
| 0XD3 |
523114 |
13 |
15 |
Moisture Curve Invalid - The digits entered are not valid. Check the data and try again. |
| 0XD3 |
523114 |
14 |
14 |
Moisture Curve Modify - You are about to modify a moisture curve. |
| 0XD3 |
523114 |
31 |
16 |
Moisture Curve Conflict - Moisture disabled. Verify Curve 1 and Curve 2 data from the Info Diagnostic page for the currently selected crop. |
| 0XD3 |
523138 |
14 |
20 |
Offset out of range - The calculated offset is out of range. It must be >-10.1 and < +10.1 Offset not modified. |
| 0XD3 |
523143 |
18 |
07 |
Low voltage - Delayed power (cc# 6) voltage at Moisture Sensor is too low. Data will be lost when vehicle turned off. Moisture disabled. Call dealer for service. |
| Control Unit |
SPN |
FMI |
Warning Messages |
Description |
| 0XD3 |
523313 |
03 |
19 |
Mass Flow out of range - Mass Flow Sensor Signal (cc# 972) voltage is too high. Please check wiring CC970, CC971, and CC972. Mass Flow disabled. Call dealer for service. |
| 0XD3 |
523313 |
04 |
18 |
Mass Flow out of range - Mass Flow Sensor Signal (cc# 972) voltage is too low. Mass Flow disabled. Please check wiring CC970, CC971, and CC972. Call dealer for service. |
| 0XD3 |
523316 |
18 |
06 |
Low voltage - Electronic Power (cc# 21) voltage at Moisture Sensor is too low. Please check wiring cc# 21 and cc# 20 |
| 0XD3 |
523951 |
16 |
11 |
High voltage - Analog voltage is too high. X volts Moisture disabled. Call dealer for service. |
| 0XD3 |
523951 |
18 |
10 |
Low voltage - Analog voltage is too low. x Volts Moisture disabled. Call dealer for service. |
| 0XD3 |
524196 |
14 |
|
Flow Compensation Reset. Indicates to the operator that continuing the Yield Calibration process will cause the loss of the current Flow Comp Setting. |
| 0XD3 |
524197 |
13 |
|
Moisture Calibration Failure. The moisture calibration procedure was not able to be complete. Make sure the engine is off and there are no plunger or motor faults active. |
| 0XD3 |
524197 |
14 |
|
Moisture Calibration Pending. Indicates to the operator that when the Continue button is pressed that a Moisture Calibration will be performed. Make sure the engine is off and the moisture sensor is empty and clean. |