Calibration Service Codes

  • ER01 Feeder house calibration must be done before header calibration procedure
  • ER02 No header connected or invalid header type
  • ER03 No corn head connected during deck plate calibration
  • ER11 Cutterbar flex pressure sensor voltage less than 0.5 V
  • ER21 HEADERTRAK Lateral tilt angle sensor voltage less than 0.5 V
  • ER22 HEADERTRAK Lateral tilt angle sensor voltage greater than 4.5 V
  • ER23 HEADERTRAK Lateral tilt angle sensor voltage noisy or changing in an incorrect direction
  • ER24 HEADERTRAK Lateral tilt angle voltage range less than 2.0 V
  • ER25 HEADERTRAK Lateral tilt angle sensor "left" voltage greater than 2.5V
  • ER26 HEADERTRAK Lateral tilt angle sensor "right" voltage less than 2.5 V
  • ER27 HEADERTRAK Lateral tilt angle sensor center voltage is not within 0.75 V of mid-range
  • ER39 Lift cylinder pressure sensor voltage less than 1.0 V (3000 kPa; 30 bar; 435 psi)
  • ER41 Deck plate position sensor voltage less than 0.5V
  • ER42 Deck plate position sensor voltage greater than 4.5V
  • ER43 Deck plate position sensor voltage noisy or changing in an incorrect direction
  • ER44 Deck plate position sensor voltage range less than 2.0 V
  • ER45 Deck plate position sensor "closed" voltage greater than 2.5 V
  • ER46 Deck plate position sensor "opened" voltage less than 2.5 V
  • ER51 Header height resume sensor voltage less than 0.5 V
  • ER52 Header height resume sensor voltage greater than 4.5 V
  • ER53 Header height resume sensor voltage noisy or changing in an incorrect direction
  • ER54 Header height resume sensor voltage range less than 2.0 V
  • ER55 Header height resume sensor "lowered" voltage greater than 2.5 V (3.0 V on corn head)
  • ER56 Header height resume sensor "raised" voltage less than 2.5 V (3.0 V on corn head)
  • ER59 Header height resume sensor has excessive hysteresis
  • ER61 Header raise valve deadband not consistent within 80mA
  • ER63 Header raise valve deadband greater than 1200mA
  • ER64 Header raise valve deadband less than 800mA
  • ER66 Header lower valve deadband not consistent within 80mA
  • ER68 Header lower valve deadband greater than 1200mA
  • ER69 Header lower valve deadband less than 800mA
  • ER71 Left height sensor voltage less than 0.5 V
  • ER72 Left height position sensor voltage greater than 4.5 V
  • ER73 Left height position sensor voltage noisy or changing in an incorrect direction
  • ER74 Left height position sensor voltage range less than 2.0 V (1.5 V for flex platforms)
  • ER75 Left height position sensor "lowered" voltage greater than 2.5 V
  • ER76 Left height position sensor "raised" voltage less than 2.5 V
  • ER77 Left and right height sensor not stopping at same feeder house position
  • ER81 Right height sensor voltage less than 0.5 V
  • ER82 Right height position sensor voltage greater than 4.5 V
  • ER83 Right height position sensor voltage noisy or changing in an incorrect direction
  • ER84 Right height position sensor voltage range less than 2.0 V (1.5 V for flex platforms)
  • ER85 Right height position sensor "lowered" voltage greater than 2.5 V
  • ER86 Right height position sensor "raised" voltage less than 2.5 V

OUO6075,0004080 -19-15AUG05-1/2


  • ER91 Flex header height sensor voltage less than 0.5 V
  • ER92 Flex header height position sensor voltage greater than 4.5 V
  • ER93 Flex header height position sensor voltage noisy or changing in an incorrect direction
  • ER94 Flex height position sensor voltage range less than 2.0 V (1.5 V for flex platforms)
  • ER95 Flex header height position sensor "lowered" voltage greater than 2.5 V
  • ER96 Flex header height position sensor "raised" voltage less than 2.5 V 1 If this service code appears then replace the valve
  • E101 Left auxiliary height position sensor 2 voltage is less than 0.5VDC
  • E102 Left auxiliary height position sensor 2 voltage is greater than 4.5VDC
  • E103 Left auxiliary height position sensor 2 voltage is noisy or going backwards
  • E104 Left auxiliary height position sensor 2 voltage range is less than 2.0VDC
  • E105 Left auxiliary height position sensor 2 lower voltage is greater than 2.5VDC
  • E106 Left auxiliary height position sensor 2 upper voltage is less than 2.5VDC
  • E111 Right auxiliary height position sensor 2 voltage is less than 0.5VDC
  • E112 Right auxiliary height position sensor 2 voltage is greater than 4.5VDC
  • E113 Right auxiliary height position sensor 2 voltage is noisy or going backwards
  • E114 Right auxiliary height position sensor 2 voltage range is less than 2.0VDC
  • E115 Right auxiliary height position sensor 2 lower voltage is greater than 2.5VDC
  • E116 Right auxiliary height position sensor 2 upper voltage is less than 2.5VDC
  • E121 Middle auxiliary height position sensor 2 voltage is less than 0.5VDC
  • E122 Middle auxiliary height position sensor 2 voltage is greater than 4.5VDC
  • E123 Middle auxiliary height position sensor 2 voltage is noisy or going backwards
  • E124 Middle auxiliary height position sensor 2 voltage range is less than 2.0VDC
  • E125 Middle auxiliary height position sensor 2 lower voltage is greater than 2.5VDC
  • E126 Middle height auxiliary position sensor 2 upper voltage is less than 2.5VDC

OUO6075,0004080 -19-15AUG05-2/2