| Control Unit |
SPN |
FMI |
Pri. |
Description |
| E01 |
627 |
03 |
1 |
Controller supply voltage out of range high - greater than 16 VDC. |
| E01 |
628 |
12 |
1 |
Controller cannot exit boot block program. Disconnect effected control unit connectors. Wait 30 seconds. Reconnect connectors. Reprogram controller with latest software. Replace control unit if condition persists. |
| E01 |
1079 |
03 |
2 |
Height Sensor Power (cc# 481) voltage is too high - greater than 5.25VDC. Height Sensor Power is used to power the Return To Cut Sensor, Reel Fore/Aft Position Sensor, Deck Plate Position Sensor, Right Header Height Sensor, Center Header Height Sensor and Left Header Height Sensor. |
| E01 |
1079 |
04 |
2 |
Height Sensor Power (cc# 481) voltage is too low - less than 4.75VDC. Height Sensor Power is used to power the Return To Cut Sensor, Reel Fore/Aft Position Sensor, Deck Plate Position Sensor, Right Header Height Sensor, Center Header Height Sensor and Left Header Height Sensor. |
| E01 |
1080 |
03 |
2 |
Height Sensor Power 2 (cc# 471) voltage is too high - greater than 5.25VDC.Height Sensor Power 2 is used to power the CONTOUR MASTER Angle Sensor and the Header Raise Pressure Sensor. The voltage regulator of the Header Control Unit is bad or there is a short circuit to voltage. |
| E01 |
1080 |
04 |
2 |
Height Sensor Power 2 (cc# 471) voltage is too low - less than 4.75VDC. Height Sensor Power 2 is used to power the CONTOUR MASTER Angle Sensor and the Header Raise Pressure Sensor. The voltage regulator of the Header Control Unit is bad or there is a short circuit to ground. |
| E01 |
1515 |
13 |
2 |
Active Header Height Control system or CONTOUR MASTER system not calibrated for currently attached header. Perform the calibration procedure. |
| E01 |
1516 |
13 |
2 |
Header Float system not calibrated for currently attached header. Perform the calibration procedure. |
| E01 |
1517 |
04 |
2 |
Header Raise Pressure (cc# 706) voltage is too low - less than 0.25VDC. |
| E01 |
1519 |
11 |
2 |
Header raise valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the Header Raise Valve until the fault condition is removed. |
| E01 |
1520 |
11 |
2 |
Header lower valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the Header Lower Valve until the fault condition is removed. |
| E01 |
1521 |
11 |
2 |
Tilt left valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the CONTOUR MASTER Tilt Left Valve until the fault condition is removed. |
| E01 |
1522 |
11 |
2 |
Tilt right valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the CONTOUR MASTER Tilt Right Valve until the fault condition is removed. |
| E01 |
1523 |
11 |
2 |
HYDRAFLEX diverter valve driver detects an open, short, over voltage, or over temperature condition. The Header Control Unit will not actuate the HYDRAFLEX Diverter Valve until the fault condition is removed. |
| E01 |
1531 |
06 |
2 |
Reel speed increase driver detects an open, short, over voltage, over temperature condition. The Header Control Unit will not actuate the Reel Speed Actuator in the increase speed mode until the fault condition is removed |
| Control Unit |
SPN |
FMI |
Pri. |
Description |
| E01 |
1532 |
06 |
2 |
Reel speed decrease driver detects an open, short, over voltage, over temperature condition. The Header Control Unit will not actuate the Reel Speed Actuator in the decrease speed mode until the fault condition is removed |
| E01 |
1533 |
03 |
2 |
Height Resume Sensor (cc# 828) voltage is too high - greater than 4.5VDC. Faulty device or wiring. |
| E01 |
1533 |
04 |
2 |
Height Resume Sensor (cc# 828) voltage is too low - less than 0.5 VDC. Faulty device or wiring. |
| E01 |
1534 |
03 |
2 |
Left Header Height Sensor (cc# 412) voltage is too high - greater than 4.5 VDC. Faulty device or wiring. |
| E01 |
1534 |
04 |
2 |
Left Header Height Sensor (cc# 412) voltage is too low less than 0.5 VDC. Faulty device or wiring. |
| E01 |
1535 |
03 |
2 |
Right Header Height Sensor (cc# 454) voltage is too high - greater than 4.5 VDC). Faulty device or wiring. |
| E01 |
1535 |
04 |
2 |
Right Header Height Sensor (cc# 454) voltage is too low - less than 0.5 VDC. Faulty device or wiring. |
| E01 |
1536 |
03 |
2 |
Center Header Height Sensor (cc# 414) voltage is too high - greater than 4.5 VDC or shorted pads of the DIAL-A-MATIC Sensor. Faulty device or wiring. |
| E01 |
1536 |
04 |
2 |
Center Header Height Sensor (cc# 414) voltage is too low - less than 0.5 VDC or no signal from DIAL-A-MATIC Sensor. Faulty device or wiring. |
| E01 |
1541 |
02 |
2 |
Reel speed unknown. |
| E01 |
298618 |
07 |
2 |
Reel raise/lower resume system has malfunctioned. |
| E01 |
298619 |
07 |
2 |
Reel fore/aft resume system has malfunctioned. |
| E01 |
298621 |
07 |
2 |
HYDRAFLEX system has malfunctioned. |
| E01 |
524260 |
03 |
2 |
Center Height Sensor 2 voltage out of range high - greater than 4.75 VDC. |
| E01 |
524260 |
04 |
2 |
Center Height Sensor 2 voltage out of range low - less than 0.25 VDC. |
| E01 |
524261 |
03 |
2 |
Right Height Sensor 2 voltage out of range high - greater than 4.75 VDC. |
| E01 |
524261 |
04 |
2 |
Right Height Sensor 2 voltage out of range low less than 0.25 VDC. |
| E01 |
524278 |
03 |
2 |
Left Height Sensor 2 voltage out or range high - greater than 4.75 VDC. |
| E01 |
524278 |
04 |
2 |
Left Height Sensor 2 voltage out of range low less than 0.25 VDC. |