| Control Unit |
SPN |
FMI |
Pri. |
Description |
| E02 |
627 |
03 |
1 |
Electronic Power (cc# 021) voltage is too high - greater than 16 VDC. |
| E02 |
628 |
12 |
1 |
Controller cannot exit boot block program. Disconnect effected control unit connectors. Wait 30 seconds. Reconnect connectors. Reprogram controller with latest software. Replace control unit if condition persists. |
| E02 |
630 |
11 |
2 |
EEPROM failed test on power up. Replace the Right Control Unit if condition persists. |
| E02 |
639 |
19 |
2 |
CAN Bus messages are not being transmitted or received correctly. Possible effects are none, slow response, or machine down. |
| E02 |
1508 |
03 |
2 |
Hydraulic Oil Temperature Sensor (cc# 775) voltage is too high - greater than 4.97 VDC. The device or wiring is faulty. |
| E02 |
1508 |
04 |
2 |
Hydraulic Oil Temperature Sensor (cc# 775) voltage is too low - less than 0.29 VDC. The device or wiring is faulty. |
| E02 |
1509 |
03 |
2 |
Main Gearcase Oil Temperature Sensor (cc# 774) voltage is too high -greater than 4.97 VDC. The device or wiring is faulty. |
| E02 |
1509 |
04 |
2 |
Main Gearcase Oil Temperature Sensor (cc# 774) voltage is too low -less than 0.29 VDC. The device or wiring is faulty. |