E02 - Right Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
E02 627 03 1 Electronic Power (cc# 021) voltage is too high - greater than 16 VDC.
E02 628 12 1 Controller cannot exit boot block program. Disconnect effected control unit connectors. Wait 30 seconds. Reconnect connectors. Reprogram controller with latest software. Replace control unit if condition persists.
E02 630 11 2 EEPROM failed test on power up. Replace the Right Control Unit if condition persists.
E02 639 19 2 CAN Bus messages are not being transmitted or received correctly. Possible effects are none, slow response, or machine down.
E02 1508 03 2 Hydraulic Oil Temperature Sensor (cc# 775) voltage is too high - greater than 4.97 VDC. The device or wiring is faulty.
E02 1508 04 2 Hydraulic Oil Temperature Sensor (cc# 775) voltage is too low - less than 0.29 VDC. The device or wiring is faulty.
E02 1509 03 2 Main Gearcase Oil Temperature Sensor (cc# 774) voltage is too high -greater than 4.97 VDC. The device or wiring is faulty.
E02 1509 04 2 Main Gearcase Oil Temperature Sensor (cc# 774) voltage is too low -less than 0.29 VDC. The device or wiring is faulty.

 