Header Reel/Belt Pickup Pump Belt-Replacing

causym CAUTION: Shut OFF engine, set parking brake and remove key.

NOTE: It is not necessary to disconnect any hydraulic hoses when replacing this belt.

Remove shields and loosen spring tensioner idler nut (A).

Remove header drive belt (see Replacing Fixed Speed Feeder House Belt).

Disconnect wire from electric clutch and remove belt (B).

Install replacement belt and adjust tensioner so washer is positioned between end of gauge and bottom of step.

Check feeder house variable sheave gap.

H62319


A-Nut
B-Belt