C00 - Armrest Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
C00 627 03 1 Delayed Power (cc# 006) voltage is above 16 VDC. High voltage situation must be resolved.
C00 628 12 1 Controller cannot exit boot block program. Disconnect effected control unit connectors. Wait 30 seconds. Reconnect connectors. Reprogram controller with latest software. Replace control unit if condition persists.
C00 630 11 1 Controller failed EEPROM test at power-up. Replace Armrest Control Unit if condition persists.
C00 1490 08 2 Feeder house speed unknown. Damage could occur to feeder house if direction is changed while feeder house is turning.
C00 1499 12 2 The separator engage fault detection circuit indicates a failure. This is an important disengagement override system. Replace the Armrest Control Unit if condition persists.
C00 1504 11 1 The Seat Switch has been closed continuously for 6 hours. The switch or the wiring harness is shorted. The header will not disengage when the operator has left the seat. This must be corrected.

 