E03 - Left Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
E03 627 03 1 Electronic Power (cc# 021) voltage is too high - greater than 15.5 VDC.
E03 628 12 1 Controller cannot exit boot block program. Disconnect effected control unit connectors. Wait 30 seconds. Reconnect connectors. Reprogram controller with latest software. Replace control unit if condition persists.
E03 876 11 2 CLIMATRAK compressor driver detects an open, short, over voltage, or over temperature condition.
E03 200112 3 2 Auger Fold Signal (cc# 396) or Auger Unfold signal (cc# 397) is ON when it should be OFF.
E03 200112 4 2 Auger Fold Signal (cc# 396) or Auger Unfold signal (cc# 397) is ON when it should be OFF.
E03 200129 11 2 Feeder house reverser (cc# 442) driver detects an open short, over voltage, or over temperature condition. The Left Control Unit cannot reverse the feeder house until the fault condition is removed.
E03 200132 11 1 Left brake light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode.
E03 200133 11 1 Right brake light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode.
E03 200134 11 1 Left marker light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode.
E03 200135 11 1 Right marker light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode.
E03 200137 11 2 Feeder house reverser driver detects an open, short, over voltage, or over temperature condition.
E03 200140 03 2 12VDC detected on Power Ground (cc# 010) of Control Relay Board. Indicates problem with ground connections.
E03 200141 04 2 12VDC not detected on Unswitched Electronic Power (cc# 022) of Control Relay Board. Indicates problem with Unswitched Electronic Power connection, wiring or Fuse F20 of the Engine Compartment Relay Panel.
E03 200142 04 2 12VDC not detected on Light Power (cc# 014) of Control Relay Board. Indicates problem with Light Power connection, wiring or Fuse F18 of the Engine Compartment Relay Panel.
E03 200143 04 2 12VDC not detected on Control Power (cc# 016) of Control Relay Board. Indicates problem with Control Power connection, wiring, Fuse F8 or Relay K4 of the Engine Compartment Relay Panel.
E03 200144 04 2 12VDC not detected on Light Power 2 (cc# 046) of Control Relay Board. Indicates problem with Light Power 2 connection, wiring or Fuse F5 of the Engine Compartment Relay Panel.
E03 200145 04 2 12VDC not detected on Light Power 3 (cc# 047) of Control Relay Board. Indicates problem with Light Power 3 connection, wiring or Fuse F3 of the Engine Compartment Relay Panel.
E03 200146 04 2 12 VDC not detected on Light Power 2 (cc# 046) of Control Relay Board. Indicates problem with Light power 2 connection, wiring or fuse F5 of the Engine Compartment Relay Panel.
E03 200147 04 2 12VDC not detected on Fan Speed Adjust Power (cc# 051) of Control Relay Board. Indicates problem with Fan Speed Adjust Power connection, wiring or Fuse F11 or Relay K5 of the Engine Compartment Relay Panel.

 

OUO6075,00004C7 -19-21JUN06-1/2


Control Unit SPN FMI Pri. Description
E03 200148 04 2 12VDC not detected on Light Power 5 (cc# 049) of Control Relay Board. Indicates problem with Light Power 5 connection, wiring or Fuse F9 of the Engine Compartment Relay Panel.
E03 200149 11 2 Indicates a problem in the serial communication link between the Left Control Unit and the Control Relay Board.
E03 200501 03 2 Auger Fold Position (cc# 836) is out of range high (greater than 4.75 VDC).
E03 200501 04 2 Auger Fold Position (cc# 836) is out of range low (less than 0.5 VDC).
E03 200501 12 2 The folding unloading auger is stalled. Auger Fold Position (cc# 836) has not changed for two seconds while attempting to move.
E03 200501 13 2 The folding auger sensor is not calibrated.
E03 200501 15 2 Auger Fold Position (cc# 836) is high (greater than 1.70 VDC) when fully folded during calibration.
E03 200501 17 2 Auger Fold Position (cc# 836) is low (less than 3.20 VDC) when fully folded during calibration.

 

OUO6075,00004C7 -19-21JUN06-2/2