| Control Unit |
SPN |
FMI |
Pri. |
Description |
| E03 |
627 |
03 |
1 |
Electronic Power (cc# 021) voltage is too high - greater than 15.5 VDC. |
| E03 |
628 |
12 |
1 |
Controller cannot exit boot block program. Disconnect effected control unit connectors. Wait 30 seconds. Reconnect connectors. Reprogram controller with latest software. Replace control unit if condition persists. |
| E03 |
876 |
11 |
2 |
CLIMATRAK compressor driver detects an open, short, over voltage, or over temperature condition. |
| E03 |
200112 |
3 |
2 |
Auger Fold Signal (cc# 396) or Auger Unfold signal (cc# 397) is ON when it should be OFF. |
| E03 |
200112 |
4 |
2 |
Auger Fold Signal (cc# 396) or Auger Unfold signal (cc# 397) is ON when it should be OFF. |
| E03 |
200129 |
11 |
2 |
Feeder house reverser (cc# 442) driver detects an open short, over voltage, or over temperature condition. The Left Control Unit cannot reverse the feeder house until the fault condition is removed. |
| E03 |
200132 |
11 |
1 |
Left brake light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode. |
| E03 |
200133 |
11 |
1 |
Right brake light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode. |
| E03 |
200134 |
11 |
1 |
Left marker light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode. |
| E03 |
200135 |
11 |
1 |
Right marker light driver detects an open, short, over voltage, or over temperature condition. Only active in the ROAD mode. |
| E03 |
200137 |
11 |
2 |
Feeder house reverser driver detects an open, short, over voltage, or over temperature condition. |
| E03 |
200140 |
03 |
2 |
12VDC detected on Power Ground (cc# 010) of Control Relay Board. Indicates problem with ground connections. |
| E03 |
200141 |
04 |
2 |
12VDC not detected on Unswitched Electronic Power (cc# 022) of Control Relay Board. Indicates problem with Unswitched Electronic Power connection, wiring or Fuse F20 of the Engine Compartment Relay Panel. |
| E03 |
200142 |
04 |
2 |
12VDC not detected on Light Power (cc# 014) of Control Relay Board. Indicates problem with Light Power connection, wiring or Fuse F18 of the Engine Compartment Relay Panel. |
| E03 |
200143 |
04 |
2 |
12VDC not detected on Control Power (cc# 016) of Control Relay Board. Indicates problem with Control Power connection, wiring, Fuse F8 or Relay K4 of the Engine Compartment Relay Panel. |
| E03 |
200144 |
04 |
2 |
12VDC not detected on Light Power 2 (cc# 046) of Control Relay Board. Indicates problem with Light Power 2 connection, wiring or Fuse F5 of the Engine Compartment Relay Panel. |
| E03 |
200145 |
04 |
2 |
12VDC not detected on Light Power 3 (cc# 047) of Control Relay Board. Indicates problem with Light Power 3 connection, wiring or Fuse F3 of the Engine Compartment Relay Panel. |
| E03 |
200146 |
04 |
2 |
12 VDC not detected on Light Power 2 (cc# 046) of Control Relay Board. Indicates problem with Light power 2 connection, wiring or fuse F5 of the Engine Compartment Relay Panel. |
| E03 |
200147 |
04 |
2 |
12VDC not detected on Fan Speed Adjust Power (cc# 051) of Control Relay Board. Indicates problem with Fan Speed Adjust Power connection, wiring or Fuse F11 or Relay K5 of the Engine Compartment Relay Panel. |
| Control Unit |
SPN |
FMI |
Pri. |
Description |
| E03 |
200148 |
04 |
2 |
12VDC not detected on Light Power 5 (cc# 049) of Control Relay Board. Indicates problem with Light Power 5 connection, wiring or Fuse F9 of the Engine Compartment Relay Panel. |
| E03 |
200149 |
11 |
2 |
Indicates a problem in the serial communication link between the Left Control Unit and the Control Relay Board. |
| E03 |
200501 |
03 |
2 |
Auger Fold Position (cc# 836) is out of range high (greater than 4.75 VDC). |
| E03 |
200501 |
04 |
2 |
Auger Fold Position (cc# 836) is out of range low (less than 0.5 VDC). |
| E03 |
200501 |
12 |
2 |
The folding unloading auger is stalled. Auger Fold Position (cc# 836) has not changed for two seconds while attempting to move. |
| E03 |
200501 |
13 |
2 |
The folding auger sensor is not calibrated. |
| E03 |
200501 |
15 |
2 |
Auger Fold Position (cc# 836) is high (greater than 1.70 VDC) when fully folded during calibration. |
| E03 |
200501 |
17 |
2 |
Auger Fold Position (cc# 836) is low (less than 3.20 VDC) when fully folded during calibration. |