| Control Unit |
SPN |
FMI |
Priority |
Description |
| E14 |
158 |
00 |
1 |
Feed rate power 12 VDC (cc# 41) is out of range high. Voltage is above 16 VDC. |
| E14 |
158 |
01 |
1 |
Feed rate power 12 VDC (cc# 41) is out of range low. Voltage is below 9 VDC. |
| E14 |
190 |
09 |
1 |
CAN Bus message missing from engine control unit - engine speed. |
| E14 |
628 |
12 |
1 |
Controller cannot exit boot block program. Disconnect effected control unit connectors. Wait 30 seconds. Reconnect connectors. Reprogram controller with latest software. Replace control unit if condition persists. |
| E14 |
200406 |
09 |
2 |
CAN Bus message missing from control unit E13 Note: Cornerpost control unit C03 will display "no E13" on fourth display. |
| E14 |
200408 |
01 |
1 |
Handle Sensor Power 5 VDC (cc# 221) is out of range low. Voltage is below 4.8 VDC. |
| E14 |
200408 |
04 |
1 |
Handle Sensor Power 5 VDC (cc# 221) shorted to ground. |
| E14 |
200408 |
13 |
2 |
Multifunction Handle Position Fault Multifunction control handle position does not match calibrated values due to faulty power supply or sensor. Check and diagnose diagnostic trouble codes on control unit E14 first. Recalibrate sensor if no other related diagnostic trouble codes are present. Go to Section 240 - Electrical System - Calibration Procedures and perform multifunction control handle position sensor calibration procedure. |
| E14 |
200410 |
00 |
2 |
Control unit E14 temperature is high. Temperature is above 70°C (150°F). |
| E14 |
200411 |
00 |
2 |
Threshing pressure signal (cc# 732) is out of range high. |
| E14 |
200411 |
01 |
2 |
Threshing pressure signal (cc# 732) is out of range low. |
| E14 |
200411 |
03 |
2 |
Threshing pressure signal (cc# 732) short to power. |
| E14 |
200411 |
04 |
2 |
Threshing pressure signal (cc# 732) short to ground. |
| E14 |
200411 |
15 |
2 |
Threshing pressure sensor not connected. One or more circuits open (cc# 730, 731, or 732), or Threshing pressure sensor is faulty. |
| E14 |
200421 |
00 |
2 |
Handle position signal (cc# 222) is out of range high. |
| E14 |
200421 |
01 |
2 |
Handle position signal (cc# 222) is out of range low. |
| E14 |
200421 |
03 |
2 |
Handle position signal (cc# 222) is shorted to power. |
| E14 |
200421 |
04 |
2 |
Handle position signal (cc# 222) is shorted to ground. |
| E14 |
200421 |
13 |
2 |
Multifunction control handle position sensor calibration required. Perform multifunction control handle position sensor calibration procedure. |
| E14 |
200421 |
15 |
2 |
Handle position signal (cc# 222) is open. Multifunction control handle position sensor not connected, faulty harness, or faulty sensor. |
| E14 |
200422 |
00 |
2 |
Handle position signal (cc# 222) is out of range high. Voltage is above 4.50 VDC. |
| E14 |
200422 |
01 |
2 |
Handle position signal (cc# 222) is out of range low. Voltage is below 0.25 VDC. |
| E14 |
200428 |
01 |
2 |
Threshing pressure signal power 5 VDC (cc# 731) is out of range low. Voltage is below 4.8 VDC. |
| E14 |
200428 |
03 |
2 |
Threshing pressure signal power 5 VDC (cc# 731) is out of range high or shorted to power. Voltage is above 5.25 VDC. |
| E14 |
200428 |
04 |
2 |
Threshing pressure signal power 5 VDC (cc# 731) shorted to ground. |
| E14 |
298682 |
09 |
2 |
CAN Bus message missing from cornerpost control unit C03 - ground speed. |