E14 - HARVESTSMART Feed Rate Control Unit (SFC) (If Equipped) Diagnostic Trouble Codes

Control Unit SPN FMI Priority Description
E14 158 00 1 Feed rate power 12 VDC (cc# 41) is out of range high. Voltage is above 16 VDC.
E14 158 01 1 Feed rate power 12 VDC (cc# 41) is out of range low. Voltage is below 9 VDC.
E14 190 09 1 CAN Bus message missing from engine control unit - engine speed.
E14 628 12 1 Controller cannot exit boot block program. Disconnect effected control unit connectors. Wait 30 seconds. Reconnect connectors. Reprogram controller with latest software. Replace control unit if condition persists.
E14 200406 09 2 CAN Bus message missing from control unit E13
Note: Cornerpost control unit C03 will display "no E13" on fourth display.
E14 200408 01 1 Handle Sensor Power 5 VDC (cc# 221) is out of range low. Voltage is below 4.8 VDC.
E14 200408 04 1 Handle Sensor Power 5 VDC (cc# 221) shorted to ground.
E14 200408 13 2 Multifunction Handle Position Fault
Multifunction control handle position does not match calibrated values due to faulty power supply or sensor. Check and diagnose diagnostic trouble codes on control unit E14 first. Recalibrate sensor if no other related diagnostic trouble codes are present. Go to Section 240 - Electrical System - Calibration Procedures and perform multifunction control handle position sensor calibration procedure.
E14 200410 00 2 Control unit E14 temperature is high. Temperature is above 70°C (150°F).
E14 200411 00 2 Threshing pressure signal (cc# 732) is out of range high.
E14 200411 01 2 Threshing pressure signal (cc# 732) is out of range low.
E14 200411 03 2 Threshing pressure signal (cc# 732) short to power.
E14 200411 04 2 Threshing pressure signal (cc# 732) short to ground.
E14 200411 15 2 Threshing pressure sensor not connected. One or more circuits open (cc# 730, 731, or 732), or Threshing pressure sensor is faulty.
E14 200421 00 2 Handle position signal (cc# 222) is out of range high.
E14 200421 01 2 Handle position signal (cc# 222) is out of range low.
E14 200421 03 2 Handle position signal (cc# 222) is shorted to power.
E14 200421 04 2 Handle position signal (cc# 222) is shorted to ground.
E14 200421 13 2 Multifunction control handle position sensor calibration required. Perform multifunction control handle position sensor calibration procedure.
E14 200421 15 2 Handle position signal (cc# 222) is open. Multifunction control handle position sensor not connected, faulty harness, or faulty sensor.
E14 200422 00 2 Handle position signal (cc# 222) is out of range high. Voltage is above 4.50 VDC.
E14 200422 01 2 Handle position signal (cc# 222) is out of range low. Voltage is below 0.25 VDC.
E14 200428 01 2 Threshing pressure signal power 5 VDC (cc# 731) is out of range low. Voltage is below 4.8 VDC.
E14 200428 03 2 Threshing pressure signal power 5 VDC (cc# 731) is out of range high or shorted to power. Voltage is above 5.25 VDC.
E14 200428 04 2 Threshing pressure signal power 5 VDC (cc# 731) shorted to ground.
E14 298682 09 2 CAN Bus message missing from cornerpost control unit C03 - ground speed.

 

OUO6075,00004CC -19-22JUN06-1/2


Control Unit SPN FMI Priority Description
E14 298805 13 2 Controller Failed EEPROM Test. Clear diagnostic trouble code. Replace control unit E14 if condition persists.
E14 298982 09 2 CAN Bus message missing from armrest control unit C00 - unloading auger drive status.
E14 298983 09 2 CAN Bus message missing from armrest control unit C00 - four wheel drive low status.
E14 298984 09 2 CAN Bus message missing from armrest control unit C00 - four wheel drive high status.
E14 299103 09 2 CAN Bus message missing from armrest control unit C00 - separator status.
E14 299165 09 2 CAN Bus message missing from right control unit E02 - grain loss.
E14 299171 09 2 CAN Bus message missing from left control unit E03 - threshing speed.

 

OUO6075,00004CC -19-22JUN06-2/2