ER01
- Feeder house calibration must be done before header calibration procedure
-
ER02
- No header connected or invalid header type
-
ER03
- No corn head connected during deck plate calibration
-
ER11
- Cutterbar flex pressure sensor voltage less than 0.5VDC
-
ER21
- CONTOUR MASTER angle sensor voltage less than 0.5VDC
-
ER22
- CONTOUR MASTER angle sensor voltage greater than 4.5VDC
-
ER23
- CONTOUR MASTER angle sensor voltage is erratic or changing in an incorrect direction
-
ER24
- CONTOUR MASTER angle sensor voltage range less than 2.0VDC
-
ER25
- CONTOUR MASTER angle "left" sensor voltage greater than 2.5VDC
-
ER26
- CONTOUR MASTER angle "right" sensor voltage less than 2.5VDC
-
ER27
- CONTOUR MASTER angle sensor center voltage not within 0.75VDC of mid-range
-
ER39
- Lift cylinder pressure sensor voltage less than 1.0VDC (3000 kPa; 30 bar; 435 psi)
-
ER41
- Deck plate position sensor voltage less than 0.5VDC
-
ER42
- Deck plate position sensor voltage greater than 4.5VDC
-
ER43
- Deck plate position sensor voltage is erratic or changing in an incorrect direction
-
ER44
- Deck plate position sensor voltage range less than 2.0VDC
-
ER45
- Deck plate position "closed" sensor voltage greater than 2.5VDC
-
ER46
- Deck plate position "opened" sensor voltage less than 2.5VDC
-
ER51
- Header height resume sensor voltage less than 0.5 VDC
-
ER52
- Header height resume sensor voltage greater than 4.5VDC
-
ER53
- Header height resume sensor voltage erratic or changing in an incorrect direction
|
-
ER54
- Header height resume sensor voltage range less than 2.0VDC
-
ER55
- Header height resume sensor "lowered" voltage greater than 2.5VDC (3.0VDC on corn head)
-
ER56
- Header height resume sensor "raised" voltage less than 2.5VDC (3.0VDC on corn head)
-
ER59
- Header height resume sensor signal has excessive hysteresis
-
ER61
- Header raise valve deadband not consistent within 80mA
1
-
ER63
- Header raise valve deadband greater than 1200mA
1
-
ER64
- Header raise valve deadband less than 800mA
1
-
ER66
- Header lower valve deadband not consistent within 80mA
1
-
ER68
- Header lower valve deadband greater than 1200mA
1
-
ER69
- Header lower valve deadband less than 800mA
1
-
ER71
- Left height sensor voltage less than 0.5VDC
-
ER72
- Left height position sensor voltage greater than 4.5VDC
-
ER73
- Left height position sensor voltage is erratic or changing in an incorrect direction
-
ER74
- Left height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
-
ER75
- Left height position sensor "lowered" voltage greater than 2.5VDC
-
ER76
- Left height position sensor "raised" voltage less than 2.5VDC
-
ER77
- Left and Right height sensors not stopping at same feeder house position
-
ER81
- Right height sensor voltage less than 0.5VDC
-
ER82
- Right height position sensor voltage greater than 4.5VDC
-
ER83
- Right height position sensor voltage is erratic or changing in an incorrect direction
-
ER84
- Right height position sensor voltage range less than 2.0VDC (1.5VDC for flex platforms)
|