Header Height Sensing

Header Height Sensing allows the operator to select the position of the header relative to the ground and return to that position automatically.

Header Height Sensing must be calibrated each time that the header is used with the combine (see Calibration Procedures section).

Activation buttons 1, 2 or 3 located on the multifunction control handle are used to select one of three different programmed header heights.

NOTE: If both Header Height Resume and Header Height Sensing are enabled, only activation button 1 will activate Header Height Resume, activation buttons 2 and 3 will then be assigned to Header Height Sensing.

Operation

Header Height Sensing will be active when:

  • Properly equipped header is connected to combine
  • Engine is running
  • Road transport disconnect switch is in field position
  • Header Height Sensing is enabled
  • Header is engaged
H71405
H74738

OUO6075,0003D77 -19-10MAR05-1/2


The system is enabled by pressing button (A) on the display. Symbol (B) will appear on the display.

Activate Header Height Sensing by pressing activation buttons 1, 2 or 3 on the multifunction control handle. Arrows symbols (C) indicate the system is active.

Number (D) in the lower left corner of the display indicates which activation button was selected.

To change the height setpoint (E) of the activation buttons, press the desired activation button and adjust the height using active header height control dial (F).

Turn active header height control dial toward the plus (+) symbol to raise the header and setpoint or towards the minus (-) symbol to lower the header and setpoint.

Bar graph (G) and number display (H) show the relative position of the header based on Header Height sensor linked to header.

Manually adjusting header height using header lower switch (I) will temporarily override the system until the switch is released. Once the switch is released the system will return to the automatic mode. Using header raise switch (I) will temporarily deactivate the system until the header lower switch is pressed. Once the switch is pressed the system will reactivate.

Press any of the activation buttons to reactivate the system. Header will move to the pre-selected height.

The system can be disabled by pressing button (A) on the display.

H74740


A-Header Height Sensing System Button
B-Header Height Sensing Symbol
C-System Active Arrows
D-Activation Button Number
E-Height Setpoint
F-Active Header Height Control Dial
G-Bar Graph
H-Number Display
I-Header Raise/Lower Switch

OUO6075,0003D77 -19-10MAR05-2/2