NOTE:
Harvesting, recording is "ON", determine how many points the moisture correction needs to be added or removed from the instantaneous moisture.
Not harvesting, recording "OFF", will display average moisture of crop. Average moisture does not need to be corrected. If average moisture is corrected, the instantaneous moisture could be over corrected.
1.
Press letter button next to "Moisture Correction" on SETUP - Moisture screen.
NOTE:
"Crop" cell displays the selected crop.
2.
Letter button next to "Moisture Correction" and "Fixed Moisture Value" allows the operator to
|
correct the moisture reading on RUN PAGE 1 by toggling to "Fixed Moisture Value", moisture sensor will be disabled and forces moisture value to what was entered.
3.
If using "Moisture Correction": Press letter button next to "Moisture Correction" and using numeric keypad input a number value to be added to reading displayed on RUN - PAGE 1 screen.
4.
Press letter button next to "Moisture Correction" again to save this value.
5.
If using fixed moisture value; Press letter button next to "Fixed Moisture Value" and using numeric keypad, input a number value (%) to be displayed on RUN - PAGE 1 screen.
|