| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
629 |
12 |
Service Alert |
Control unit LC1 has reset itself due to watchdog timer. |
| LC1 |
639 |
12 |
Service Alert |
CAN Bus 1 message is not arriving on time or missing. Reserved by JDOS but disabled. |
| LC1 |
639 |
14 |
Service Alert |
No CAN Bus 1 messages are arriving. Reserved by JDOS but disabled. |
| LC1 |
740 |
03 |
Service Alert |
Shift lock solenoid (cc# 209) is ON when commanded OFF by control unit LC1. |
| LC1 |
740 |
05 |
Service Alert |
Shift lock solenoid (cc# 209) is open circuit. |
| LC1 |
740 |
06 |
Service Alert |
Shift lock solenoid (cc# 209) is OFF when commanded ON by control unit LC1. |
| LC1 |
1231 |
09 |
Service Alert |
Local CAN Bus message is not arriving on time or missing. |
| LC1 |
1388 |
03 |
Service Alert |
Rotor drive pressure (cc# 723) out of range high. |
| LC1 |
1388 |
04 |
Service Alert |
Rotor drive pressure (cc# 723) out of range low. |
| LC1 |
1486 |
00 |
Calibration |
Threshing clearance (cc# 833) calibration voltage is out of range at maximum - greater than 4.5 VDC. |
| LC1 |
1486 |
01 |
Calibration |
Threshing clearance (cc# 833) calibration voltage is out of range at minimum - less than 0.5 VDC. |
| LC1 |
1486 |
03 |
Service Alert |
Threshing clearance sensor (cc# 833) out of range high. |
| LC1 |
1486 |
04 |
Service Alert |
Threshing clearance sensor (cc# 833) out of range low. |
| LC1 |
1486 |
13 |
Information |
Threshing clearance sensor not calibrated. |
| LC1 |
1489 |
03 |
Service Alert |
Cleaning fan speed (cc# 606) has no signal. Sensor voltage out of range high. |
| LC1 |
1489 |
04 |
Service Alert |
Cleaning fan speed (cc# 606) has no signal. Sensor voltage out of range low. |
| LC1 |
1493 |
12 |
Service Alert |
Tailings monitor system failure. Tailings sensors have read the same value for 10 seconds and are not full. |
| LC1 |
1496 |
03 |
Service Alert |
Tailings elevator speed (cc# 616) has no signal. Sensor voltage out of range high. |
| LC1 |
1496 |
04 |
Service Alert |
Tailings elevator speed (cc# 616) has no signal. Sensor voltage out of range low. |
| LC1 |
1498 |
03 |
Stop |
Header engage (cc# 401) is ON when commanded OFF by control unit LC1. |
| LC1 |
1498 |
05 |
Service Alert |
Header engage (cc# 401) is open circuit. |
| LC1 |
1498 |
06 |
Service Alert |
Header engage (cc# 401) is OFF when commanded ON by control unit LC1. |
| LC1 |
1498 |
12 |
Service Alert |
Driver for header engage (cc# 401) is faulty. |
| LC1 |
1515 |
13 |
Information |
Header not calibrated. |
| LC1 |
1517 |
03 |
Service Alert |
Header lift cylinder pressure sensor (cc# 704) is out of range - greater than 4.5 VDC. |
| LC1 |
1517 |
04 |
Service Alert |
Header lift cylinder pressure sensor (cc# 704) is out of range - less than 0.5 VDC. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
1518 |
02 |
Information |
Voltage of cc# 431, 433, 434 or 435 changed while operating in automatic header height control mode. |
| LC1 |
1519 |
00 |
Calibration |
Feeder house Raise/Lower Speed Calibration - The feeder house did not raise when the applied current was greater than 1500mA |
| LC1 |
1519 |
01 |
Calibration |
Feeder house Raise/Lower Speed Calibration - The feeder house began raising when the applied current was less than 500mA |
| LC1 |
1519 |
03 |
Service Alert |
Header raise solenoid (cc# 427) is ON when commanded OFF by control unit LC1. |
| LC1 |
1519 |
04 |
Service Alert |
Header raise solenoid (cc# 427) is OFF when commanded ON by control unit LC1. |
| LC1 |
1519 |
05 |
Service Alert |
Header raise solenoid (cc# 427) is open circuit. |
| LC1 |
1519 |
06 |
Service Alert |
Header raise solenoid (cc# 427) is over current. |
| LC1 |
1519 |
12 |
Service Alert |
Driver for header raise solenoid (cc# 427) is faulty. |
| LC1 |
1519 |
13 |
Service Alert |
Feeder house raise/lower speed calibration has not been performed. |
| LC1 |
1520 |
00 |
Calibration |
Feeder house Raise/Lower Speed Calibration - The feeder house did not lower when the applied current was greater than 1500mA |
| LC1 |
1520 |
01 |
Calibration |
Feeder house Raise/Lower Speed Calibration - The feeder house began lowering when the applied current was less than 500mA |
| LC1 |
1520 |
03 |
Service Alert |
Header lower solenoid (cc# 407) is ON when commanded OFF by control unit LC1. |
| LC1 |
1520 |
04 |
Service Alert |
Header lower solenoid (cc# 407) is OFF when commanded ON by control unit LC1. |
| LC1 |
1520 |
05 |
Service Alert |
Header lower solenoid (cc# 407) is open circuit. |
| LC1 |
1520 |
06 |
Service Alert |
Header lower solenoid (cc# 407) is over current. |
| LC1 |
1520 |
12 |
Service Alert |
Driver for header lower solenoid (cc# 407) is faulty. |
| LC1 |
1521 |
03 |
Service Alert |
Header tilt left solenoid (cc# 408) is ON when commanded OFF by control unit LC1. |
| LC1 |
1521 |
05 |
Service Alert |
Header tilt left solenoid (cc# 408) is open circuit. |
| LC1 |
1521 |
06 |
Service Alert |
Header tilt left solenoid (cc# 408) is OFF when commanded ON by control unit LC1. |
| LC1 |
1521 |
12 |
Service Alert |
Driver for header tilt left solenoid (cc# 408) is faulty. |
| LC1 |
1522 |
03 |
Service Alert |
Header tilt right solenoid (cc# 409) is ON when commanded OFF by control unit LC1. |
| LC1 |
1522 |
05 |
Service Alert |
Header tilt right solenoid (cc# 409) is open circuit. |
| LC1 |
1522 |
06 |
Service Alert |
Header tilt right solenoid (cc# 409) is OFF when commanded ON by control unit LC1. |
| LC1 |
1522 |
12 |
Service Alert |
Driver for header tilt right solenoid (cc# 409) is faulty. |
| LC1 |
1524 |
03 |
Service Alert |
Reel extend solenoid (cc# 418) is ON when commanded OFF by control unit LC1. |
| LC1 |
1524 |
05 |
Service Alert |
Reel extend solenoid (cc# 418) is open circuit. |
| LC1 |
1524 |
06 |
Service Alert |
Reel extend solenoid (cc# 418) is OFF when commanded ON by control unit LC1. |
| LC1 |
1524 |
12 |
Service Alert |
Driver for reel extend solenoid (cc# 418) is faulty. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
1525 |
03 |
Service Alert |
Reel retract solenoid (cc# 419) is ON when commanded OFF by control unit LC1. |
| LC1 |
1525 |
05 |
Service Alert |
Reel retract solenoid (cc# 419) is open circuit. |
| LC1 |
1525 |
06 |
Service Alert |
Reel retract solenoid (cc# 419) is OFF when commanded ON by control unit LC1. |
| LC1 |
1525 |
12 |
Service Alert |
Driver for reel retract solenoid (cc# 419) is faulty. |
| LC1 |
1526 |
03 |
Service Alert |
Reel raise solenoid (cc# 416) is ON when commanded OFF by control unit LC1. |
| LC1 |
1526 |
05 |
Service Alert |
Reel raise solenoid (cc# 416) is open circuit. |
| LC1 |
1526 |
06 |
Service Alert |
Reel raise solenoid (cc# 416) is OFF when commanded ON by control unit LC1. |
| LC1 |
1526 |
12 |
Service Alert |
Driver for reel raise solenoid (cc# 416) is faulty. |
| LC1 |
1527 |
03 |
Service Alert |
Reel lower solenoid (cc# 415) is ON when commanded OFF by control unit LC1. |
| LC1 |
1527 |
05 |
Service Alert |
Reel lower solenoid (cc# 415) is open circuit. |
| LC1 |
1527 |
06 |
Service Alert |
Reel lower solenoid (cc# 415) is OFF when commanded ON by control unit LC1. |
| LC1 |
1527 |
12 |
Service Alert |
Driver for reel lower solenoid (cc# 415) is faulty. |
| LC1 |
1529 |
03 |
Service Alert |
Accumulator shutoff solenoid (cc# 484) is ON when commanded OFF by control unit LC1. |
| LC1 |
1529 |
05 |
Service Alert |
Accumulator shutoff solenoid (cc# 484) is open circuit. |
| LC1 |
1529 |
06 |
Service Alert |
Accumulator shutoff solenoid (cc# 484) is OFF when commanded ON by control unit LC1. |
| LC1 |
1529 |
12 |
Service Alert |
Driver for accumulator shutoff solenoid (cc# 484) is faulty. |
| LC1 |
1533 |
03 |
Service Alert |
Feeder house position sensor (cc# 814) is out of range - greater than 4.5 VDC. |
| LC1 |
1533 |
04 |
Service Alert |
Feeder house position sensor (cc# 814) is out of range - less than 0.5 VDC. |
| LC1 |
1534 |
00 |
Calibration |
Header Calibration - left height sensor (cc# 816) voltage is too high - greater than 4.75 VDC. |
| LC1 |
1534 |
01 |
Calibration |
Header Calibration - left height sensor (cc# 816) voltage is too low - less than 0.25 VDC (Sensor is expected since right header height sensor was detected). |
| LC1 |
1534 |
03 |
Service Alert |
Left header height sensor (cc# 816) is out of range - greater than 4.5 VDC. |
| LC1 |
1534 |
04 |
Service Alert |
Left header height sensor (cc# 816) is out of range - less than 0.5 VDC. |
| LC1 |
1534 |
07 |
Calibration |
Header Calibration - left height sensor (cc# 816) voltage range is less than 2.00 VDC. |
| LC1 |
1534 |
10 |
Calibration |
Header Calibration - center height sensor (cc# 817) raised voltage is less than lowered voltage. |
| LC1 |
1535 |
00 |
Calibration |
Header Calibration - right height sensor (cc# 818) voltage is too high - greater than 4.75 VDC. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
1535 |
01 |
Calibration |
Header Calibration - right height sensor (cc# 818) voltage is too low - less than 0.25 VDC (Sensor is expected since left header height sensor was detected). |
| LC1 |
1535 |
03 |
Service Alert |
Right header height sensor (cc# 818) is out of range - greater than 4.5 VDC. |
| LC1 |
1535 |
04 |
Service Alert |
Right header height sensor (cc# 818) is out of range - less than 0.5 VDC. |
| LC1 |
1535 |
07 |
Calibration |
Header Calibration - right height sensor (cc# 818) voltage range is less than 2.00 VDC. |
| LC1 |
1535 |
10 |
Calibration |
Header Calibration - right height sensor (cc# 818) raised voltage is less than lowered voltage. |
| LC1 |
1536 |
00 |
Calibration |
Header Calibration - center height sensor (cc# 817) voltage is too high - greater than 4.75 VDC. |
| LC1 |
1536 |
03 |
Service Alert |
Center header height sensor (cc# 817) is out of range - greater than 4.5 VDC. |
| LC1 |
1536 |
04 |
Service Alert |
Center header height sensor (cc# 817) is out of range - less than 0.5 VDC. |
| LC1 |
1536 |
07 |
Calibration |
Header Calibration - center height sensor (cc# 817) voltage range is less than 2.00 VDC. |
| LC1 |
1536 |
10 |
Calibration |
Header Calibration - left height sensor (cc# 816) raised voltage is less than lowered voltage. |
| LC1 |
1554 |
03 |
Service Alert |
Grain elevator speed (cc# 607) has no signal. Sensor voltage out of range - high. |
| LC1 |
1554 |
04 |
Service Alert |
Grain elevator speed (cc# 607) has no signal. Sensor voltage out of range - low. |
| LC1 |
1867 |
03 |
Service Alert |
LPC1 micro power (cc# 102) is ON when commanded OFF by control unit LC1. |
| LC1 |
1867 |
06 |
Service Alert |
LPC1 micro power (cc# 102) is OFF when commanded ON by control unit LC1. |
| LC1 |
2354 |
03 |
Service Alert |
Left stubble lights (cc# 564) is ON when commanded OFF by Left power module 1. |
| LC1 |
2354 |
05 |
Service Alert |
Left stubble lights (cc# 564) is open circuit. |
| LC1 |
2354 |
06 |
Service Alert |
Left stubble lights (cc# 564) is OFF when commanded ON by Left power module 1. |
| LC1 |
2378 |
03 |
Service Alert |
Left front marker light (cc# 556) is ON when commanded OFF by control unit LC1. |
| LC1 |
2378 |
05 |
Service Alert |
Left front marker light (cc# 556) is open circuit. |
| LC1 |
2378 |
06 |
Service Alert |
The Left front marker light (cc# 556) is OFF when commanded ON. |
| LC1 |
2378 |
12 |
Service Alert |
Driver for left front marker light (cc# 556) is faulty. |
| LC1 |
3004 |
03 |
Service Alert |
Draper speed increase (cc# 455) and/or draper speed decrease (cc# 456) is ON when commanded OFF by control unit LC1. |
| LC1 |
3004 |
05 |
Service Alert |
Draper speed increase (cc# 455) and/or draper speed decrease (cc# 456) is open circuit. |
| LC1 |
3004 |
06 |
Service Alert |
Draper speed increase (cc# 455) is OFF when commanded ON by control unit LC1. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
3005 |
06 |
Service Alert |
Draper speed decrease (cc# 456) is OFF when commanded ON by control unit LC1. |
| LC1 |
3010 |
03 |
Service Alert |
Threshing speed solenoid (cc# 329) is ON when commanded OFF by control unit LC1. |
| LC1 |
3010 |
05 |
Service Alert |
Threshing speed solenoid (cc# 329) is open circuit. |
| LC1 |
3010 |
06 |
Service Alert |
Threshing speed solenoid (cc# 329) is OFF when commanded ON by control unit LC1. |
| LC1 |
3010 |
12 |
Service Alert |
Driver for threshing speed solenoid (cc# 329) is faulty. |
| LC1 |
3014 |
03 |
Service Alert |
Threshing clearance increase (cc# 323) and/or Threshing clearance decrease (cc# 324) is ON when commanded OFF by control unit LC1. |
| LC1 |
3014 |
05 |
Service Alert |
Threshing clearance decrease (cc# 324) and/or threshing clearance increase (cc# 323) is open circuit. |
| LC1 |
3014 |
06 |
Service Alert |
Threshing clearance increase (cc# 323) is OFF when commanded ON by control unit LC1. |
| LC1 |
3015 |
06 |
Service Alert |
Threshing clearance decrease (cc# 324) is OFF when commanded ON by control unit LC1. |
| LC1 |
3102 |
03 |
Service Alert |
Auger swing extend solenoid (cc# 317) is ON when commanded OFF by control unit LC1. |
| LC1 |
3102 |
05 |
Service Alert |
Auger swing extend solenoid (cc# 317) is open circuit. |
| LC1 |
3102 |
06 |
Service Alert |
Auger swing extend solenoid (cc# 317) is OFF when commanded ON by control unit LC1. |
| LC1 |
3102 |
12 |
Service Alert |
Driver for auger swing extend solenoid (cc# 317) is faulty. |
| LC1 |
3103 |
03 |
Service Alert |
Auger swing retract solenoid (cc# 316) is ON when commanded OFF by control unit LC1. |
| LC1 |
3103 |
05 |
Service Alert |
Auger swing retract solenoid (cc# 316) is open circuit. |
| LC1 |
3103 |
06 |
Service Alert |
Auger swing retract solenoid (cc# 316) is OFF when commanded ON by control unit LC1. |
| LC1 |
3103 |
12 |
Service Alert |
Driver for auger swing retract solenoid (cc# 316) is faulty. |
| LC1 |
3120 |
03 |
Service Alert |
Unloading auger fold (cc# 398) and/or unloading auger unfold (cc# 399) is ON when commanded OFF. |
| LC1 |
3120 |
05 |
Service Alert |
Unloading auger fold (cc# 398) and/or unloading auger unfold (cc# 399) is open circuit. |
| LC1 |
3120 |
06 |
Service Alert |
Unloading auger fold (cc# 398) is OFF when commanded ON. |
| LC1 |
3121 |
06 |
Service Alert |
Unloading auger unfold (cc# 399) is OFF when commanded ON. |
| LC1 |
3333 |
00 |
Calibration |
Feeder house Height Range Calibration - The maximum feeder house position sensor (cc# 814) voltage is too high - greater than 4.75 VDC. |
| LC1 |
3333 |
01 |
Calibration |
Feeder house Height Range Calibration - The minimum feeder house position sensor (cc# 814) voltage is too low - less than 0.25 VDC. |
| LC1 |
3333 |
13 |
Service Alert |
Feeder house height range calibration has not been performed. |
| LC1 |
3333 |
15 |
Calibration |
Feeder house Raise/Lower Speed Calibration - The feeder house raised too far during calibration and might have hit the end stop if the calibration continued. Please repeat the calibration starting with the feeder house lower to the ground. |
| LC1 |
3333 |
16 |
Calibration |
Feeder house Height Range Calibration - The minimum feeder house position sensor (cc# 814) voltage is too high - greater than 3.00 VDC. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
3333 |
17 |
Calibration |
Feeder house Raise/Lower Speed Calibration - The feeder house lowered too far during calibration and might have hit the end stop if the calibration continued. Please repeat the calibration starting with the feeder house lower to the ground. |
| LC1 |
3333 |
18 |
Calibration |
Feeder house Height Range Calibration - The maximum feeder house position sensor (cc# 814) voltage is too low - less than 3.00 VDC. |
| LC1 |
3509 |
03 |
Service Alert |
LC1 sensor supply 1 (cc# 253) is too high - greater than 5.50 VDC. |
| LC1 |
3509 |
04 |
Service Alert |
LC1 sensor supply 1 (cc# 253) is too low - less than 4.50 VDC. |
| LC1 |
3510 |
03 |
Service Alert |
LC1 8 VDC sensor supply (cc# 267) is too high - greater than 8.50 VDC. |
| LC1 |
3510 |
04 |
Service Alert |
LC1 8 VDC sensor supply (cc# 267) is too low - less than 7.50 VDC. |
| LC1 |
3597 |
04 |
Service Alert |
LC1 PTC power (cc# 606) output too low. |
| LC1 |
522312 |
03 |
Service Alert |
Windshield washer pump (cc# 924) is ON when commanded OFF by control unit LC1. |
| LC1 |
522312 |
05 |
Service Alert |
Windshield washer pump (cc# 924) is open circuit. |
| LC1 |
522312 |
06 |
Service Alert |
Windshield washer pump (cc# 924) is OFF when commanded ON by control unit LC1. |
| LC1 |
522312 |
12 |
Service Alert |
Driver for windshield washer pump (cc# 924) is faulty. |
| LC1 |
522779 |
03 |
Service Alert |
Cutter bar pressure sensor (cc# 813) is out of range - greater than 4.5 VDC. |
| LC1 |
522779 |
04 |
Service Alert |
Cutter bar pressure sensor (cc# 813) is out of range - less than 0.5 VDC. |
| LC1 |
522779 |
07 |
Calibration |
Header Calibration - cutterbar pressure (cc# 813) voltage is out of range high or low. Calibration will not proceed. |
| LC1 |
523132 |
03 |
Service Alert |
Reel diverter solenoid (cc# 417) is ON when commanded OFF by control unit LC1. |
| LC1 |
523132 |
05 |
Service Alert |
Reel diverter solenoid (cc# 417) is open circuit. |
| LC1 |
523132 |
06 |
Service Alert |
Reel diverter solenoid (cc# 417) is OFF when commanded ON by control unit LC1. |
| LC1 |
523132 |
12 |
Service Alert |
Driver for reel diverter solenoid (cc# 417) is faulty. |
| LC1 |
523319 |
03 |
Service Alert |
LC1 12V switched power (cc# 802) is ON when commanded OFF by control unit LC1. |
| LC1 |
523319 |
06 |
Service Alert |
LC1 12V switched power (cc# 802) is OFF when commanded ON by control unit LC1. |
| LC1 |
523554 |
00 |
Calibration |
Deck Plates Calibration - With deck plates fully open, deck plates sensor (cc# 834) voltage is too high - greater than 4.50 VDC. |
| LC1 |
523554 |
01 |
Calibration |
Deck Plates Calibration - With deck plates fully closed, deck plates sensor (cc# 834) voltage is too low - less than 0.50 VDC. |
| LC1 |
523554 |
03 |
Service Alert |
Reel/plate position (cc# 834) voltage is out of range - greater than 4.5 VDC. |
| LC1 |
523554 |
04 |
Service Alert |
Reel/plate position (cc# 834) voltage is out of range - less than 0.5 VDC. |
| LC1 |
523554 |
07 |
Service Alert |
Desired reel/plate position was not reached within 15 seconds. |
| LC1 |
523554 |
13 |
Service Alert |
Deck plates are detected, but the deck plate calibration has not been performed. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
523554 |
16 |
Calibration |
Deck Plates Calibration - With deck plates fully closed, deck plates sensor (cc# 834) voltage is too high - greater than 2.00 VDC. |
| LC1 |
523554 |
18 |
Calibration |
Deck Plates Calibration - With deck plates fully open, deck plates sensor (cc# 834) voltage is too low - less than 3.00 VDC. |
| LC1 |
523556 |
03 |
Service Alert |
Reel fore/aft diverter (cc# 464) is ON when commanded OFF by control unit LC1. |
| LC1 |
523556 |
05 |
Service Alert |
Reel fore/aft diverter (cc# 464) is open circuit. |
| LC1 |
523556 |
06 |
Service Alert |
Reel fore/aft diverter (cc# 464) is OFF when commanded ON by control unit LC1. |
| LC1 |
523556 |
12 |
Service Alert |
Driver for reel fore/aft diverter (cc# 464) is faulty. |
| LC1 |
523557 |
03 |
Service Alert |
Header tilt diverter (cc# 463) is ON when commanded OFF by control unit LC1. |
| LC1 |
523557 |
05 |
Service Alert |
Header tilt diverter (cc# 463) is open circuit. |
| LC1 |
523557 |
06 |
Service Alert |
Header tilt diverter (cc# 463) is OFF when commanded ON by control unit LC1. |
| LC1 |
523557 |
12 |
Service Alert |
Driver for header tilt diverter (cc# 463) is faulty. |
| LC1 |
523558 |
03 |
Service Alert |
Feed accelerator speed (cc# 626) has no signal. Sensor voltage is out of range low. |
| LC1 |
523558 |
04 |
Service Alert |
Feed accelerator speed (cc# 626) has no signal. Sensor voltage is out of range high. |
| LC1 |
523559 |
03 |
Service Alert |
Left row finder light (cc# 524) is ON when commanded OFF by left power module 1. |
| LC1 |
523559 |
05 |
Service Alert |
Left row finder light (cc# 524) is open circuit. |
| LC1 |
523559 |
06 |
Service Alert |
Left row finder light (cc# 524) is OFF when commanded ON by left power module 1. |
| LC1 |
523560 |
03 |
Service Alert |
Grain tank light (cc# 526) is ON when commanded OFF by left power module 1. |
| LC1 |
523560 |
05 |
Service Alert |
Grain tank light (cc# 526) is open circuit. |
| LC1 |
523560 |
06 |
Service Alert |
Grain tank light (cc# 526) is OFF when commanded ON by left power module 1. |
| LC1 |
523562 |
03 |
Service Alert |
Conveyor auger speed (cc# 608) has no signal. Sensor voltage out of range high. |
| LC1 |
523562 |
04 |
Service Alert |
Conveyor auger speed (cc# 608) has no signal. Sensor voltage out of range low. |
| LC1 |
523566 |
03 |
Service Alert |
Reel reverse solenoid (cc# 443) is ON when commanded OFF by control unit LC1. |
| LC1 |
523566 |
05 |
Service Alert |
Reel reverse solenoid (cc# 443) is open circuit. |
| LC1 |
523566 |
06 |
Service Alert |
Reel reverse solenoid (cc# 443) is OFF when commanded ON by control unit LC1. |
| LC1 |
523566 |
12 |
Service Alert |
Driver for reel reverse solenoid (cc# 443) is faulty. |
| LC1 |
523567 |
00 |
Calibration |
Folding auger position (cc# 835 ) calibration voltage when straight is out of range high - greater than 4.50 VDC. |
| LC1 |
523567 |
01 |
Calibration |
Folding auger position (cc# 835 ) calibration voltage when folded is out of range low - less than 0.50 VDC. |
| LC1 |
523567 |
03 |
Service Alert |
Folding auger position (cc# 835 ) is too high - greater than 4.50 VDC. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
523567 |
04 |
Service Alert |
Folding auger position (cc# 835 ) is too low - less than 0.50 VDC. |
| LC1 |
523567 |
12 |
Service Alert |
Folding unloading auger is stalled. |
| LC1 |
523567 |
13 |
Information |
Folding unloading auger position sensor is not calibrated. |
| LC1 |
523567 |
16 |
Calibration |
Folding auger position (cc# 835 ) calibration voltage when folded is out of range high - greater than 2.50 VDC. |
| LC1 |
523567 |
18 |
Service Alert |
Folding auger position (cc# 835 ) calibration voltage when straight is out of range low - less than 2.50 VDC. |
| LC1 |
523576 |
03 |
Service Alert |
Feeder house reverse solenoid (cc# 411) is ON when commanded OFF by control unit LC1. |
| LC1 |
523576 |
05 |
Service Alert |
Feeder house reverse solenoid (cc# 411) is open circuit. |
| LC1 |
523576 |
06 |
Service Alert |
Feeder house reverse solenoid (cc# 411) is OFF when commanded ON by control unit LC1. |
| LC1 |
523576 |
12 |
Service Alert |
Driver for feeder house reverse solenoid (cc# 411) is faulty. |
| LC1 |
523583 |
03 |
Service Alert |
Cutter bar diverter solenoid (cc# 457) is ON when commanded OFF by control unit LC1. |
| LC1 |
523583 |
05 |
Service Alert |
Cutter bar diverter solenoid (cc# 457) is open circuit. |
| LC1 |
523583 |
06 |
Service Alert |
Cutter bar diverter solenoid (cc# 457) is OFF when commanded ON by control unit LC1. |
| LC1 |
523583 |
07 |
Service Alert |
Desired cutterbar pressure was not reached within 30 seconds. |
| LC1 |
523583 |
12 |
Service Alert |
Driver for cutter bar diverter solenoid (cc# 457) is faulty. |
| LC1 |
523585 |
03 |
Service Alert |
Reel speed adjust solenoid (cc# 425) is ON when commanded OFF by control unit LC1. |
| LC1 |
523585 |
04 |
Service Alert |
Reel speed adjust solenoid (cc# 425) is OFF when commanded ON by control unit LC1. |
| LC1 |
523585 |
05 |
Service Alert |
Reel speed adjust solenoid (cc# 425) is open circuit. |
| LC1 |
523585 |
06 |
Service Alert |
Reel speed adjust solenoid (cc# 425) is over current. |
| LC1 |
523585 |
12 |
Service Alert |
Driver for reel speed adjust solenoid (cc# 425) is faulty. |
| LC1 |
523586 |
03 |
Service Alert |
Reel height (cc# 837) voltage is out of range - greater than 4.5 VDC. |
| LC1 |
523586 |
04 |
Service Alert |
Reel height (cc# 837) voltage is out of range - less than 0.5 VDC. |
| LC1 |
523586 |
07 |
Service Alert |
Desired reel height was not reached within 15 seconds. |
| LC1 |
523587 |
03 |
Service Alert |
Unload solenoid (cc# 458) is ON when commanded OFF by control unit LC1. |
| LC1 |
523587 |
05 |
Service Alert |
Unload solenoid (cc# 458) is open circuit. |
| LC1 |
523587 |
06 |
Service Alert |
Unload solenoid (cc# 458) is OFF when commanded ON by control unit LC1. |
| LC1 |
523587 |
12 |
Service Alert |
Driver for unload solenoid (cc# 458) is faulty. |
| LC1 |
523589 |
03 |
Service Alert |
Unloading auger light (cc# 525) is ON when commanded OFF by control unit LC1. |
| LC1 |
523589 |
05 |
Service Alert |
Unloading auger light (cc# 525) is open circuit. |
| LC1 |
523589 |
06 |
Service Alert |
Unloading auger light (cc# 525) is OFF when commanded ON by control unit LC1. |
| LC1 |
523589 |
12 |
Service Alert |
Driver for unloading auger light (cc# 525) is faulty. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
523597 |
03 |
Service Alert |
Left beacon (cc# 575) is ON when commanded OFF by control unit LC1. |
| LC1 |
523597 |
05 |
Service Alert |
Left beacon (cc# 575) is open circuit. |
| LC1 |
523597 |
06 |
Service Alert |
Left beacon (cc# 575) is OFF when commanded ON by control unit LC1. |
| LC1 |
523597 |
12 |
Service Alert |
Driver for left beacon (cc# 575) is faulty. |
| LC1 |
523611 |
03 |
Service Alert |
Left rear discharge light (cc# 566) is ON when commanded OFF by left power module 1. |
| LC1 |
523611 |
05 |
Service Alert |
Left rear discharge light (cc# 566) is open circuit. |
| LC1 |
523611 |
06 |
Service Alert |
Left rear discharge light (cc# 566) is OFF when commanded ON by left power module 1. |
| LC1 |
523622 |
11 |
Service Alert |
LPC1 power 5 (cc# 172) is less than 4.5 VDC at the left power module 1 input. |
| LC1 |
523648 |
11 |
Service Alert |
LPC1 power 4 (cc# 142) is less than 4.5 VDC at the left power module 1 input. |
| LC1 |
523649 |
11 |
Service Alert |
LPC1 power 3 (cc# 132) is less than 4.5 VDC at the left power module 1 input. |
| LC1 |
523650 |
11 |
Service Alert |
LPC1 power 2 (cc# 122) is less than 4.5 VDC at the left power module 1 input. |
| LC1 |
523653 |
11 |
Service Alert |
LPC1 power 1 (cc# 112) is less than 4.5 VDC at the left power module 1 input. |
| LC1 |
523665 |
11 |
Service Alert |
LC1 power 2 (cc# 152) is less than 4. VDC at the control unit LC1 input. |
| LC1 |
523666 |
11 |
Service Alert |
LC1 power 1 (cc# 162) is less than 4. VDC at the control unit LC1 input. |
| LC1 |
523673 |
05 |
Service Alert |
Control unit LC1 driver circuits are not grounded. |
| LC1 |
523919 |
03 |
Service Alert |
Gullwing service lights (cc# 594) is ON when commanded OFF by left power module 1. |
| LC1 |
523919 |
05 |
Service Alert |
Gullwing service lights (cc# 594) is open circuit. |
| LC1 |
523919 |
06 |
Service Alert |
Gullwing service lights (cc# 594) is OFF when commanded ON by left power module 1. |
| LC1 |
524260 |
00 |
Calibration |
Header Calibration - center height sensor 2 (cc# 803) voltage is too high - greater than 4.75 VDC. Calibration will not proceed. |
| LC1 |
524260 |
03 |
Service Alert |
Center header height sensor 2 (cc# 803) is out of range - greater than 4.5 VDC. |
| LC1 |
524260 |
04 |
Service Alert |
Center header height sensor 2 (cc# 803) is out of range - less than 0.5 VDC. |
| LC1 |
524260 |
07 |
Calibration |
Header Calibration - center height sensor 2 (cc# 803) voltage range is less than 2.00 VDC. |
| LC1 |
524260 |
10 |
Calibration |
Header Calibration - center height sensor 2 (cc# 803) raised voltage is less than lowered voltage. |
| LC1 |
524261 |
00 |
Calibration |
Header Calibration - right height sensor 2 (cc# 828) voltage is too high - greater than 4.75 VDC. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC1 |
524261 |
01 |
Calibration |
Header Calibration - right height sensor 2 (cc# 828) voltage is too low - less than 0.25 VDC (Sensor is expected since auxiliary left header height sensor was detected). |
| LC1 |
524261 |
03 |
Service Alert |
Right header height sensor 2 (cc# 818) is out of range - greater than 4.5 VDC. |
| LC1 |
524261 |
04 |
Service Alert |
Right header height sensor 2 (cc# 818) is out of range - less than 0.5 VDC. |
| LC1 |
524261 |
07 |
Calibration |
Header Calibration - right height sensor 2 (cc# 828) voltage range is less than 2.00 VDC. |
| LC1 |
524261 |
10 |
Calibration |
Header Calibration - right height sensor 2 (cc# 828) raised voltage is less than lowered voltage. |
| LC1 |
524278 |
00 |
Calibration |
Header Calibration - left height sensor 2 (cc# 826) voltage is too high - greater than 4.75 VDC. |
| LC1 |
524278 |
01 |
Calibration |
Header Calibration - left height sensor 2 (cc# 826) voltage is too low - less than 0.25 VDC (Sensor is expected since auxiliary right header height sensor was detected). |
| LC1 |
524278 |
03 |
Service Alert |
Left header height sensor 2 (cc# 826) is out of range - greater than 4.5 VDC. |
| LC1 |
524278 |
04 |
Service Alert |
Left header height sensor 2 (cc# 826) is out of range - less than 0.5 VDC. |
| LC1 |
524278 |
07 |
Calibration |
Header Calibration - left height sensor 2 (cc# 826) voltage range is less than 2.00 VDC. |
| LC1 |
524278 |
10 |
Calibration |
Header Calibration - left height sensor 2 (cc# 826) raised voltage is less than lowered voltage. |