| Control Unit |
SPN |
FMI |
Priority |
Description |
| HMM |
629 |
12 |
Information |
Moisture sensor has reset itself due to watchdog timer. |
| HMM |
3509 |
18 |
Service Alert |
AMS power (cc# 912) voltage too low, less than 8V. Data may be lost when key switch is turned off. |
| HMM |
3510 |
16 |
Service Alert |
Mass flow sensor supply (cc# 938) voltage too high, greater than 5.35V. |
| HMM |
3510 |
18 |
Service Alert |
Mass flow sensor supply (cc# 938) voltage too low, less than 4.65V. |
| HMM |
3511 |
16 |
Service Alert |
Internal analog voltage too high, greater than 2.7V. |
| HMM |
3511 |
18 |
Service Alert |
Internal analog voltage too low, less than 2.3V. |
| HMM |
201000 |
02 |
Information |
Grain is too dry to measure. |
| HMM |
522878 |
16 |
Service Alert |
Over temperature. Moisture sensor will not operate when temperature is greater than 85 °C. |
| HMM |
523105 |
12 |
Service Alert |
Motor failed to move plunger. |
| HMM |
523105 |
14 |
Service Alert |
Motor failed to move plunger during initialization. |
| HMM |
523106 |
11 |
Service Alert |
Relay failure. |
| HMM |
523107 |
06 |
Service Alert |
Motor shorted. |
| HMM |
523107 |
07 |
Service Alert |
Plunger initialization failure. |
| HMM |
523313 |
03 |
Service Alert |
Mass flow sensor signal (cc# 939) is too high. |
| HMM |
523313 |
04 |
Service Alert |
Mass flow sensor signal (cc# 939) is too low. |
| HMM |
523316 |
18 |
Service Alert |
RCU 12V switched voltage (cc# 922) too low, less than 10V. |