Diagnostic Trouble Codes - HMM - Moisture Sensor

Control Unit SPN FMI Priority Description
HMM 629 12 Information Moisture sensor has reset itself due to watchdog timer.
HMM 3509 18 Service Alert AMS power (cc# 912) voltage too low, less than 8V. Data may be lost when key switch is turned off.
HMM 3510 16 Service Alert Mass flow sensor supply (cc# 938) voltage too high, greater than 5.35V.
HMM 3510 18 Service Alert Mass flow sensor supply (cc# 938) voltage too low, less than 4.65V.
HMM 3511 16 Service Alert Internal analog voltage too high, greater than 2.7V.
HMM 3511 18 Service Alert Internal analog voltage too low, less than 2.3V.
HMM 201000 02 Information Grain is too dry to measure.
HMM 522878 16 Service Alert Over temperature. Moisture sensor will not operate when temperature is greater than 85 °C.
HMM 523105 12 Service Alert Motor failed to move plunger.
HMM 523105 14 Service Alert Motor failed to move plunger during initialization.
HMM 523106 11 Service Alert Relay failure.
HMM 523107 06 Service Alert Motor shorted.
HMM 523107 07 Service Alert Plunger initialization failure.
HMM 523313 03 Service Alert Mass flow sensor signal (cc# 939) is too high.
HMM 523313 04 Service Alert Mass flow sensor signal (cc# 939) is too low.
HMM 523316 18 Service Alert RCU 12V switched voltage (cc# 922) too low, less than 10V.

 

OUO6075,0000B4A -19-03AUG07-1/1