Every 250 Hours

H86852
H86867
H86869


A-Oil Filter
B-Drain


C-Cap
D-Dipstick


E-Fuel Tank Breather


F-Hose

IMPORTANT: Change oil every 100 hours if fuel is more than 0.5 % sulfur.

Fill crankcase with seasonal viscosity grade oil or Torq-Gard Supreme ™ (250 hours change interval). If using Plus-50 ™ oil and a John Deere filter, service interval can be extended by 50 percent. Example: 250 Hours extends to 375 Hours.

1. Engine Crank Case Oil Filter - Remove and replace oil filter (A).

2. Engine Crank Case Oil - Open drain (B) to remove oil.

3. Engine Crank Case Oil - Remove cap (C) to fill and check oil level with dipstick (D) after filling.

Torq-Gard Supreme is a trademark of Deere & Company
Plus-50 is a trademark of Deere & Company

OUO6075,00008EF -19-17DEC07-1/2


4. Fuel Tank Breather - Visually inspect fuel tank breather (E). Do not allow debris to collect on
breather. Remove fuel tank breather from hose (F) and clean.

OUO6075,00008EF -19-17DEC07-2/2