| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC2 |
629 |
12 |
Service Alert |
Control unit LC2 has reset itself due to watchdog timer. |
| LC2 |
639 |
14 |
Service Alert |
No CAN Bus messages are arriving. |
| LC2 |
1231 |
12 |
Service Alert |
Local CAN Bus message is not arriving on time or missing. |
| LC2 |
1510 |
03 |
Service Alert |
Chopper vane position (cc# 824) is out of range - greater than 4.5 VDC. |
| LC2 |
1510 |
04 |
Service Alert |
Chopper vane position (cc# 824) is out of range - less than 0.5 VDC. |
| LC2 |
1510 |
13 |
Information |
Chopper vane position (cc# 824) requires calibration. |
| LC2 |
1554 |
03 |
Service Alert |
Grain elevator speed (cc# 607) has no signal. Sensor voltage is out of range high. |
| LC2 |
1554 |
04 |
Service Alert |
Grain elevator speed (cc# 607) has no signal. Sensor voltage is out of range low. |
| LC2 |
1762 |
03 |
Service Alert |
Hydro charge pressure (cc# 707) has voltage present when the engine is running. |
| LC2 |
1867 |
03 |
Service Alert |
LPM2 micro power (cc# 202) is ON when commanded OFF by control unit LC2. |
| LC2 |
1867 |
06 |
Service Alert |
LPM2 micro power (cc# 202) is OFF when commanded ON by control unit LC2. |
| LC2 |
3509 |
03 |
Service Alert |
LC2 sensor supply 1 (cc# 273) is out of range - greater than 5.5 VDC. |
| LC2 |
3509 |
04 |
Service Alert |
LC2 sensor supply 1 (cc# 273) is out of range - less than 4.5 VDC. |
| LC2 |
3510 |
03 |
Service Alert |
LC2 sensor supply 2 (cc# 287) is out of range - greater than 8.5 VDC. |
| LC2 |
3510 |
04 |
Service Alert |
LC2 sensor supply 2 (cc# 287) is out of range - less than 7.5 VDC. |
| LC2 |
3778 |
03 |
Service Alert |
Chopper position (cc# 877) is out of range high. |
| LC2 |
3778 |
04 |
Service Alert |
Chopper position (cc# 877) is out of range low. |
| LC2 |
3597 |
04 |
Service Alert |
LC2 PTC power (cc# 542) is out of range - less than 4.0 VDC. |
| LC2 |
523319 |
03 |
Service Alert |
LC2 12V switched power (cc# 812) is ON when commanded OFF. |
| LC2 |
523319 |
06 |
Service Alert |
LC2 12V switched power (cc# 812) is OFF when commanded ON. |
| LC2 |
523495 |
06 |
Service Alert |
Chopper vane angle right (cc# 333) is OFF when commanded ON by control unit LC2. |
| LC2 |
523502 |
06 |
Service Alert |
Sieve 1 close (cc# 367) is OFF when commanded ON by control unit LC2. |
| LC2 |
523503 |
11 |
Service Alert |
Chaffer close switch (cc# 384) is greater than 4 VDC for over 30 seconds. |
| LC2 |
523508 |
00 |
Calibration |
Sieve tilt position (cc# 863) is valid but greater than 3.0 VDC when centered during calibration. |
| LC2 |
523508 |
01 |
Calibration |
Sieve tilt position (cc# 863) is valid but less than 2.0 VDC when centered during calibration. |
| LC2 |
523508 |
03 |
Service Alert |
Sieve tilt position (cc# 863) is out of range high. |
| LC2 |
523508 |
04 |
Service Alert |
Sieve tilt position (cc# 863) is out of range low. |
| LC2 |
523508 |
07 |
Service Alert |
Desired sieve position not reached. |
| LC2 |
523508 |
16 |
Calibration |
Sieve tilt position (cc# 863) is valid but greater than 2.0 VDC when fully right during calibration. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC2 |
523508 |
18 |
Calibration |
Sieve tilt position (cc# 863) is valid but less than 3.0 VDC when fully left during calibration. |
| LC2 |
523509 |
00 |
Calibration |
Chaffer tilt position (cc# 853) is valid but greater than 3.0 VDC when centered during calibration. |
| LC2 |
523509 |
01 |
Calibration |
Chaffer tilt position (cc# 853) is valid but less than 2.0 VDC when centered during calibration. |
| LC2 |
523509 |
03 |
Service Alert |
Chaffer tilt position (cc# 853) is out of range high. |
| LC2 |
523509 |
04 |
Service Alert |
Chaffer tilt position (cc# 853) is out of range low. |
| LC2 |
523509 |
09 |
Service Alert |
Desired chaffer position not reached. |
| LC2 |
523509 |
13 |
Information |
Chaffer tilt position (cc# 853) and sieve tilt position (cc# 863) require calibration. |
| LC2 |
523509 |
16 |
Calibration |
Chaffer tilt position (cc# 853) is valid but greater than 2.0 VDC when fully right during calibration. |
| LC2 |
523509 |
18 |
Calibration |
Chaffer tilt position (cc# 853) is valid but less than 3.0 VDC when fully left during calibration. |
| LC2 |
523510 |
03 |
Service Alert |
Chassis tilt lower solenoid (cc# 946) is ON when commanded OFF by control unit LC2. |
| LC2 |
523510 |
05 |
Service Alert |
Chassis tilt lower solenoid (cc# 946) is open circuit. |
| LC2 |
523510 |
06 |
Service Alert |
Chassis tilt lower solenoid (cc# 946) is OFF when commanded ON by control unit LC2. |
| LC2 |
523511 |
03 |
Service Alert |
Right two speed four wheel drive solenoid (cc# 201) is ON when commanded OFF by left power module 2. |
| LC2 |
523511 |
05 |
Service Alert |
Right two speed four wheel drive solenoid (cc# 201) is open circuit. |
| LC2 |
523511 |
06 |
Service Alert |
Right two speed four wheel drive solenoid (cc# 201) is OFF when commanded ON by left power module 2. |
| LC2 |
523512 |
03 |
Service Alert |
Left two speed four wheel drive solenoid (cc# 204) is ON when commanded OFF by left power module 2. |
| LC2 |
523512 |
05 |
Service Alert |
Left two speed four wheel drive solenoid (cc# 204) is open circuit. |
| LC2 |
523512 |
06 |
Service Alert |
Left two speed four wheel drive solenoid (cc# 204) is OFF when commanded ON by left power module 2. |
| LC2 |
523515 |
06 |
Service Alert |
Sieve 2 close (cc# 347) is OFF when commanded ON by control unit LC2. |
| LC2 |
523516 |
03 |
Service Alert |
Sieve 2 open (cc# 346) and/or sieve 2 close (cc# 347) is ON when commanded OFF by control unit LC2. |
| LC2 |
523516 |
05 |
Service Alert |
Sieve 2 open (cc# 346) and/or sieve 2 close (cc# 347) is open circuit. |
| LC2 |
523516 |
06 |
Service Alert |
Sieve 2 open (cc# 346) is OFF when commanded ON by control unit LC2. |
| LC2 |
523516 |
11 |
Information |
Right sieve actuator failed calibration. Pulses present on sieve 2 position (cc# 829). Limit switch remains on. |
| LC2 |
523517 |
06 |
Service Alert |
Chaffer 2 close (cc# 377) is OFF when commanded ON by control unit LC2. |
| LC2 |
523518 |
03 |
Service Alert |
Chaffer 2 open (cc# 376) and/or chaffer 2 close (cc# 377) is ON when commanded OFF by control unit LC2. |
| LC2 |
523518 |
05 |
Service Alert |
Chaffer 2 open (cc# 376) and/or chaffer 2 close (cc# 377) is open circuit. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC2 |
523518 |
06 |
Service Alert |
Chaffer 2 open (cc# 376) is OFF when commanded ON by control unit LC2. |
| LC2 |
523518 |
11 |
Information |
Right chaffer actuator failed calibration. Pulses present on chaffer 2 position (cc# 849). Limit switch remains on. |
| LC2 |
523521 |
03 |
Service Alert |
Sieve 1 open (cc# 366) and/or sieve 1 close (cc# 367) is ON when commanded OFF by control unit LC2. |
| LC2 |
523521 |
05 |
Service Alert |
Sieve 1 open (cc# 366) and/or sieve 1 close (cc# 367) is open circuit. |
| LC2 |
523521 |
06 |
Service Alert |
Sieve 1 open (cc# 366) is OFF when commanded ON by control unit LC2. |
| LC2 |
523521 |
11 |
Information |
Left sieve actuator failed calibration. Pulses present on sieve 1 position (cc# 841). Limit switch remains on. |
| LC2 |
523522 |
11 |
Service Alert |
Sieve close switch (cc# 394) is greater than 4 VDC for over 30 seconds. |
| LC2 |
523539 |
11 |
Service Alert |
Sieve open switch (cc# 393) is greater than 4 VDC for over 30 seconds. |
| LC2 |
523540 |
11 |
Service Alert |
Chaffer open switch (cc# 383) is greater than 4 VDC for over 30 seconds. |
| LC2 |
523541 |
03 |
Service Alert |
Backup alarm (cc# 903) is ON when commanded OFF by left power module. |
| LC2 |
523541 |
06 |
Service Alert |
Backup alarm (cc# 903) is OFF when commanded ON by left power module 2. |
| LC2 |
523542 |
00 |
Calibration |
Chaffer tilt position (cc# 853) is valid but greater than 3.0 VDC when centered during calibration. |
| LC2 |
523542 |
01 |
Calibration |
Chaffer tilt position (cc# 853) is valid but less than 2.0 VDC when centered during calibration. |
| LC2 |
523542 |
03 |
Service Alert |
Chassis tilt position (cc# 873) is out of range high. |
| LC2 |
523542 |
04 |
Service Alert |
Chassis tilt position (cc# 873) is out of range low. |
| LC2 |
523542 |
13 |
Information |
Chassis tilt position (cc# 873) and sieve tilt position (cc# 863) require calibration. |
| LC2 |
523543 |
03 |
Service Alert |
Chassis tilt unload solenoid (cc# 949) is ON when commanded OFF by control unit LC2. |
| LC2 |
523543 |
05 |
Service Alert |
Chassis tilt unload solenoid (cc# 949) is open circuit. |
| LC2 |
523543 |
06 |
Service Alert |
Chassis tilt unload solenoid (cc# 949) is OFF when commanded ON by control unit LC2. |
| LC2 |
523544 |
03 |
Service Alert |
Chassis tilt right solenoid (cc# 948) is ON when commanded OFF by control unit LC2. |
| LC2 |
523544 |
05 |
Service Alert |
Chassis tilt right solenoid (cc# 948) is open circuit. |
| LC2 |
523544 |
06 |
Service Alert |
Chassis tilt right solenoid (cc# 948) is OFF when commanded ON by control unit LC2. |
| LC2 |
523545 |
03 |
Service Alert |
Chassis tilt left solenoid (cc# 947) is ON when commanded OFF by control unit LC2. |
| LC2 |
523545 |
05 |
Service Alert |
Chassis tilt left solenoid (cc# 947) is open circuit. |
| LC2 |
523545 |
06 |
Service Alert |
Chassis tilt left solenoid (cc# 947) is OFF when commanded ON by control unit LC2. |
| Control Unit |
SPN |
FMI |
Priority |
Description |
| LC2 |
523546 |
03 |
Service Alert |
Chopper speed (cc# 617) has no signal. Sensor voltage is out of range high. |
| LC2 |
523546 |
04 |
Service Alert |
Chopper speed (cc# 617) has no signal. Sensor voltage is out of range low. |
| LC2 |
523547 |
03 |
Service Alert |
Chopper vane angle right (cc# 333) and/or chopper vane angle left (cc# 334) is ON when commanded OFF by control unit LC2. |
| LC2 |
523547 |
05 |
Service Alert |
Chopper vane angle right (cc# 333) and/or chopper vane angle left (cc# 334) is open circuit. |
| LC2 |
523547 |
06 |
Service Alert |
Chopper vane angle left (cc# 334) is OFF when commanded ON by control unit LC2. |
| LC2 |
523549 |
13 |
Information |
Sieve actuators are not calibrated. |
| LC2 |
523549 |
16 |
Information |
Sieve 1 and sieve 2 actuators are not synchronized. |
| LC2 |
523550 |
13 |
Information |
Chaffer actuators are not calibrated. |
| LC2 |
523550 |
16 |
Information |
Chaffer 1 and chaffer 2 actuators are not synchronized. |
| LC2 |
523552 |
06 |
Service Alert |
Chaffer 1 close (cc# 307) is OFF when commanded ON by control unit LC2. |
| LC2 |
523561 |
11 |
Information |
Left chaffer actuator failed calibration. Pulses present on chaffer 1 position (cc# 809). Limit switch remains on. |
| LC2 |
523561 |
03 |
Service Alert |
Chaffer 1 open (cc# 306) and/or chaffer 1 close (cc# 307) is ON when commanded OFF by control unit LC2. |
| LC2 |
523561 |
05 |
Service Alert |
Chaffer 1 open (cc# 306) and/or chaffer 1 close (cc# 307) is open circuit. |
| LC2 |
523561 |
06 |
Service Alert |
Chaffer 1 open (cc# 306) is OFF when commanded ON by control unit LC2. |
| LC2 |
523565 |
03 |
Service Alert |
Left rear marker lights (cc# 554) output is ON when commanded OFF by control unit LC2. |
| LC2 |
523565 |
05 |
Service Alert |
Left rear marker lights (cc# 554) output is open circuit. |
| LC2 |
523565 |
06 |
Service Alert |
Left rear marker lights (cc# 554) output is OFF when commanded ON by control unit LC2. |
| LC2 |
523611 |
03 |
Service Alert |
Left rear discharge light (cc# 566) is ON when commanded OFF by left power module 2. |
| LC2 |
523611 |
05 |
Service Alert |
Left rear discharge light (cc# 566) is open circuit. |
| LC2 |
523611 |
06 |
Service Alert |
Left rear discharge light (cc# 566) is OFF when commanded ON by left power module 2. |
| LC2 |
523637 |
03 |
Service Alert |
Four wheel drive engage solenoid (cc# 203) is ON when commanded OFF by left power module 2. |
| LC2 |
523637 |
05 |
Service Alert |
Four wheel drive engage solenoid (cc# 203) is open circuit. |
| LC2 |
523637 |
06 |
Service Alert |
Four wheel drive engage solenoid (cc# 203) is OFF when commanded ON by left power module 2. |
| LC2 |
523648 |
11 |
Service Alert |
LPC2 power 4 (cc# 262) is less than 4.5 VDC at the left power module 1 input. |
| LC2 |
523665 |
05 |
Service Alert |
LC2 power 1 (cc# 252) at connector X339 is less than 4.0 VDC. |