Height Resume
Height Resume allows you to select position of the feeder house
relative to the machine and return to that position automatically.
Modify When:
-
Changing crop height throughout the same field.
-
Changing the header type.
-
Ground terrain changes.
-
Changing from cutting on-ground to cutting off-ground.
System Is Enabled When:
-
Properly equipped header is connected to the machine.
-
Engine is running.
-
Road transport disconnect switch is in field position.
-
Height Resume system is ON.
-
Header is engaged.

H116962-UN-19DEC16
Auto Control
Procedure to Modify:
-
Select Auto Control on Header application main screen.
-

H116165-UN-19DEC16
ON/OFF
Select to turn Height Resume ON/OFF.

H116168-UN-19DEC16
Alert Icon
If the automation option has issues preventing it from being
enabled, the ON/OFF toggle is replaced with an alert icon. Selecting
this button brings up information to aid in troubleshooting the issues.
NOTE: Depending on machine configurations and the setup
of your configurable switches and buttons on the multi-function lever,
many combinations exist.
-

H116346-UN-19DEC16
Activation Buttons
Press the desired activation button.
Height Resume will return to last known adjustment setting.

H116353-UN-19DEC16
Height Resume
Height Resume icon appears on the corner post display.

H116354-UN-19DEC16
Activation Number
Activation number on the corner post display indicates which
button was selected.
-

H116347-UN-20DEC16
Adjustment Dial
Adjust height using header adjustment dial.
-
Turn header adjustment dial clockwise to raise the header and
setpoint.
-
Turn header adjustment dial counterclockwise to lower the header
and setpoint.

H116356-UN-20DEC16
Bar Graph
Bar graph on the corner post display shows the header's relative
position based on header height sensor linked to the header.

H118305-UN-19DEC16
Numeric Display
Numeric display on the corner post display shows the header's
relative position based on header height sensor linked to the header.

H116348-UN-19DEC16
Raise/Lower
Using the header raise/lower switch temporarily deactivates
system.
Pressing and holding the header raise/lower switch for
5 s disables the system.
Press activation buttons 1, 2, or 3 to reactivate system. Header
automatically moves to last known setting.
-

H116648-UN-19DEC16
Close
Select to close.
|
|
SS43267,00007EE-19-20170516
|
|