Threshing Clearance (Standard Concave Adjust)
This procedure calibrates Threshing Clearance by identifying
the fully opened and closed positions of the concaves. A properly
calibrated Threshing Clearance provides the best results for the harvest
setting recommendation. See your Operator's Manual for more details.
Calibration should not be completed with round bar
concave covers installed. An incorrect zero position results.
Perform Calibration When:
-
Before each harvest season.
-
Physical concave opening does not match what is being displayed
in the cab.
-
Concaves are replaced with a new or different set of concaves.
-
Threshing clearance sensor, or associated components are replaced/adjusted.
Items Accessible on Threshing Clearance Page:

N120226-UN-23FEB16
Begin Calibration
Begin Calibration—begin calibration
procedure.
Requirements—machine state required
for calibration.
Details Displayed on Page:
|
Last Calibration
|
Date and Time
|
|
Recommended Interval
|
As Needed
|
|
Estimated Time Required
|
Approximately 1-2 min
|
|
|