Yield Calibration

This procedure calibrates the estimated yield. Calibration is done by matching recorded samples with corresponding scale weight measurements.

Yield Calibration must be performed every year and in every crop that is harvested to achieve accurate grain weight measurements. Also, verify that Mass Flow Vibration Calibration has been performed for each crop.

Perform Calibration When:

  • Control unit AYM or associated components are replaced/adjusted.
  • Yield totals do not match scale tickets.
  • Highest accuracy of yield totals desired.

Items Accessible on Yield Calibration Page:

H119365
H119365-UN-18JAN17

Calibration Quality

Calibration Quality—indicates the quality of the calibration samples.

H119417
H119417-UN-18JAN17

Status

Status Indicator—indicates the status of sample recording.

H119235
H119235-UN-18JAN17

Record

Record—collect sample data.

H119363
H119363-UN-18JAN17

Unmatched Samples

Unmatched Samples—number of samples not matched to an actual weight.

H119364
H119364-UN-18JAN17

Match Scale Weight

Match Scale Weight—match recorded sample weight to actual weight of sample.

N118004
N118004-UN-22OCT15

Advanced Settings

Advanced Settings—access further adjustments and less common settings.

If Mass Flow Vibration Calibration is not current, then it is recommended to perform that calibration before performing Yield Calibration.