Wings (Folding Corn Head)
This procedure calibrates Folding Corn Head by folding and unfolding
the wings of the corn head and measuring associated sensor voltage
at each position. This allows the system to detect the position of
each wing. This prevents mechanical damage to the combine or equipment
by not allowing the header to contact the machine if the wings are
folded or engage in any other non-desired condition.
Perform Calibration When:
-
First time each header is connected to combine.
-
Mechanical adjustments have been made to the head.
-
Folding corn head wing position sensor, or associated components
are replaced/adjusted.
Items Accessible on Folding Corn Head Page:

N120226-UN-23FEB16
Begin Calibration
Begin Calibration—begin calibration
procedure.
Requirements—machine state required
for calibration.
Details Displayed on Page:
|
Last Calibration
|
Date and Time
|
|
Recommended Interval
|
As Needed
|
|
Estimated Time Required
|
Approximately 3-4 min
|
|
|
SS43267,0000859-19-20170517
|
|