Reel and Cutterbar Position
This procedure calibrates Reel and Cutterbar by extending/retracting
the cutterbar and moving the reel to the minimum and maximum positions
to associate the mechanical limits with sensor voltages. Performing
this calibration allows the control unit to calculate positions and
prevent potential damaging collisions between the Reel and Cutterbar.
Perform Calibration When:
-
Reel/Cutterbar position sensors or associated components are
replaced/adjusted.
Items Accessible on Reel and Cutterbar Page:

N120226-UN-23FEB16
Begin Calibration
Begin Calibration—begin calibration
procedure.
Requirements—machine state required
for calibration.
Details Displayed on Page:
|
Last Calibration
|
Date and Time
|
|
Recommended Interval
|
As Needed
|
|
Estimated Time Required
|
Approximately 3-4 min
|
|
|
SS43267,000085A-19-20170517
|
|