Yield | Edit/Select Calibration
Edit/Select Calibration allows you to choose samples to use
for manual calibration. Edit sample scale weights or delete samples.
Modify When:
-
Specific samples must be selected to obtain accurate yield.
-
Automatic selection does not perform as desired.
-
A new sample is not necessary.
-
Incorrect scale weight was entered for a sample.
Procedure to Modify Selected Samples:
-

H119411-UN-18JAN17
Manual Calibration
Select Manual Calibration.
-

H119412-UN-18JAN17
Edit/Select Samples
Select Edit/Select Samples button.
-

N118434-UN-23FEB16
Checkmark
Select checkmarks next to desired samples to use for calibration.
For the most accurate calibration, select samples that
are high quality, have a 0-3 percent margin, and represent the three
flow ranges.

H119411-UN-18JAN17
Manual Calibration
Procedure to Modify Scale Weight:
-
Select Manual Calibration.
-

H119412-UN-18JAN17
Edit/Select Samples
Select Edit/Select Samples button.
-

H119415-UN-18JAN17
Sample
Select sample to modify.
-

H119416-UN-18JAN17
Edit Scale Weight
Select Edit Scale Weight.
-
Enter desired scale weight using the keypad.
-

N118093-UN-16FEB16
Save
Select Save button to confirm.
-

N118396-UN-17FEB16
Close
Select Close button to return to the previous page.

H119411-UN-18JAN17
Manual Calibration
Procedure to Delete a Sample:
-
Select Manual Calibration.
-

H119412-UN-18JAN17
Edit/Select Samples
Select Edit/Select Samples button.
-

H119415-UN-18JAN17
Sample
Select sample to delete.
-

H119408-UN-18JAN17
Delete Sample
Select Delete Sample.
-

H114654-UN-05JAN17
OK
Select OK button to confirm.

N118094-UN-18JAN17
Cancel
Select Cancel button to return to the previous screen without
making any changes.
-

N118093-UN-16FEB16
Save
Select Save button to finalize.
|
|
SS43267,000087A-19-20170118
|
|