Moisture Correction

Moisture Correction allows you to toggle between Moisture Correction or Fixed Moisture, adjust the value when moisture percentage measured by combine moisture sensor differs from the elevator certified moisture, and disable moisture sensor reading and force a preset moisture value.

Modify To:

  • Toggle between moisture correction and fixed moisture.
  • Change amount of correction needed to match a certified moisture reading.
  • Change fixed moisture level used when the fixed moisture feature is enabled.

H114785
H114785-UN-10JAN17

Checked

Moisture Correction Procedure:

Set moisture correction to difference between combine moisture sensor and elevator certified moisture sensor. {Example: elevator moisture (13%) minus combine measured moisture (12%) = moisture difference (+1%)}

  1. If Use Fixed Moisture is checked, deselect checkbox to enable Correction.

  2. H119132
    H119132-UN-10JAN17

    Value

    Select to open number pad and enter desired value.



  3. H114789
    H114789-UN-10JAN17

    OK

    Select OK to save value.



Moisture correction can be a positive or negative number.

H114786
H114786-UN-10JAN17

Unchecked

Fixed Moisture Procedure:

  1. If Use Fixed Moisture is not checked, select checkbox to enable.

  2. H119133
    H119133-UN-10JAN17

    Value

    Select to open number pad and enter desired value.



  3. H114789
    H114789-UN-10JAN17

    OK

    Select OK to save value.



SS43267,00008BB-19-20170117