Moisture Correction
Moisture Correction allows you to toggle between Moisture Correction
or Fixed Moisture, adjust the value when moisture percentage measured
by combine moisture sensor differs from the elevator certified moisture,
and disable moisture sensor reading and force a preset moisture value.
Modify To:
-
Toggle between moisture correction and fixed moisture.
-
Change amount of correction needed to match a certified moisture
reading.
-
Change fixed moisture level used when the fixed moisture feature
is enabled.

H114785-UN-10JAN17
Checked
Moisture Correction Procedure:
Set moisture correction to difference between combine moisture
sensor and elevator certified moisture sensor. {Example: elevator
moisture (13%) minus combine measured moisture (12%) = moisture difference
(+1%)}
-
If Use Fixed Moisture is checked, deselect checkbox to enable
Correction.
-

H119132-UN-10JAN17
Value
Select to open number pad and enter desired value.
-

H114789-UN-10JAN17
OK
Select OK to save value.
Moisture correction can be a positive or negative number.

H114786-UN-10JAN17
Unchecked
Fixed Moisture Procedure:
-
If Use Fixed Moisture is not checked, select checkbox to enable.
-

H119133-UN-10JAN17
Value
Select to open number pad and enter desired value.
-

H114789-UN-10JAN17
OK
Select OK to save value.
|
|
SS43267,00008BB-19-20170117
|
|