Feeder House Conveyor Drive Chain-Adjusting

causym CAUTION: Raise feeder house, lower safety stop, shut OFF engine, set parking brake and remove key.

Open right-hand front shield.

Loosen nut (A) and push sprocket rearward.

NOTE: Do not over tighten feeder conveyor drive chain. It is acceptable for the chain to ride on the plastic guide.

Use pry bar in holes of inside plate to move sprocket forward and tighten nut (A).

Tighten nut and close right-hand shield.

H90960


A-Nut