Attach Multi-Coupler and Single Point Latching

IMPORTANT: Do not actuate latch pins with header on ground. If multi-coupler must be actuated with header on ground, unhook cable from handle.

Remove cover (A) and clean multi-coupler face (B).


A-Cover
B-Multi-Coupler Face

H90927
H90928

OUO6075,0000012 -19-26JUN08-1/6


Open handle (A) and remove multi-coupler (B) from storage bracket (C).


A-Handle
B-Multi-Coupler
C-Storage Bracket

H70035

OUO6075,0000012 -19-26JUN08-2/6


NOTE: To prevent damage to latching cable, a shear screw is attached to the handle. Attempts to actuate latching pins with header on ground results in screw shearing. (See Extra Shear Screw Location later in this section.)

Install multi-coupler (A) onto receptacle (B).

Pull and hold button lock (C) to close handle (D).


A-Multi-Coupler
B-Receptacle
C-Button Lock
D-Handle

H82378

OUO6075,0000012 -19-26JUN08-3/6


IMPORTANT: Failure to close multi-coupler fully so button lock can engage could result in header falling off while harvesting or transporting.

When multi-coupler handle is fully closed, button lock (A) automatically locks couplers together.


A-Button Lock

H87894

OUO6075,0000012 -19-26JUN08-4/6


NOTE: With header attached, latch pins must move freely through latch plate holes. If latch pins do not extend through latch plates, make sure that latching plates on header are properly adjusted.

Latch pins (A) must move freely through latch plate holes in header when multi-coupler is latched. Latch plate (B) must make contact with bracket (C). Less clearance (D) must be maintained between bottom of plate and pin rather than top of plate (E) and pin. This may require latch plate to be flipped.

If adjustment is needed: Remove cap screws (F), flip plate (D) end for end and reinstall.

Tighten cap screws to M10 or M12 specification.

Specification

Inside Latch Plate (M10 Cap Screws) -Torque 80 N·m (60 lb-ft)

Specification

Outside Latch Plate (M12 Cap Screws) -Torque 130 N·m (96 lb-ft)


A-Latch Pin
B-Latching Plate
C-Bottom Bracket
D-Gap
E-Top Of Plate
F-Cap Screws

H81307

Inside Latch Plate (M10 Cap Screws)

H81308

Outside Latch Plate (M12 Cap Screws)

OUO6075,0000012 -19-26JUN08-5/6


Install multi-coupler cover (A) on platform storage position.

Remove telescopic shaft from storage position and install onto feeder house backshaft, making sure quick attach collar locks fully.


A-Cover

H74305