Single Point Latching-Adjusting

NOTE: Contour-Master Feeder House: Adjustments must only be made to cable at multi-coupler handle.

Open left-hand feeder house shield (A).

Loosen cable jam nuts (B).

IMPORTANT: Verify handle is against stop on multi-coupler. Failure to verify that handle is against stop results in inaccurate pin dimensions and could result in header falling off while harvesting or transporting.

Rest multi-coupler handle against stop.


A-Shield
B-Jam Nuts

H90929
H90930

OUO6075,0000013 -19-25JUN08-1/4


NOTE: Moving cable "up" in bracket pulls pin farther in.

Moving cable "down" in bracket pushes pin farther out.

Adjust cable in bracket as needed for proper pin adjustment:

  • Left-hand latching pin must be flush to +/- 2 mm (A).


A-Dimension

H90931

Left-Hand Latching Pin

OUO6075,0000013 -19-25JUN08-2/4


Hold bottom jam nut (B) and tighten top jam nut (A).


A-Top Jam Nut
B-Bottom Jam Nut

H90932

OUO6075,0000013 -19-25JUN08-3/4


IMPORTANT: Failure to verify that pins are set to specified dimensions could result in header falling off while harvesting or transporting.

Fully lower multi-coupler handle (A) and verify pins (B) (both sides) are set to specification. Readjust if not set to specification.

Specification

Feeder House Pins -Distance 45-52 mm (1-3/4 in. - 2 in.)


A-Multi-Coupler Handle
B-Pins

H81287
H90933

OUO6075,0000013 -19-25JUN08-4/4