Chaffer/Sieve Remote Shoe Adjust Motor (Self-Leveling Shoe)-Manual Adjust

causym CAUTION: Shut OFF engine, set parking brake and remove key to help prevent accidental starting and personal injury.

NOTE: Same manual adjust procedure can be used on chaffer or sieve motor.

Two center chaffer bays must be removed to adjust sieve bay motor.

1. Remove cap screws (A-C) and shield (D).

H91029


A-Cap Screws (4 Used)
B-Cap Screws (4 Used)
C-Cap Screws (3 Used)
D-Shield

OUO6075,0000070 -19-24APR08-1/3


IMPORTANT: To prevent adjusting motor damage, do not use wrench on knob.

2. Use knob (A) to adjust motor. Turn knob clockwise to close and counterclockwise to open chaffer/sieve.


A-Knob

H91057

OUO6075,0000070 -19-24APR08-2/3


NOTE: Motor must be calibrated if it is repaired or replaced, see Calibration Procedures section.

3. Distance (A) between adjust motors (B) and linkage bar (C) must be set the same to allow louvers to open and close freely.


A-Distance
B-Adjust Motor
C-Linkage Bar

H91245

OUO6075,0000070 -19-24APR08-3/3