Manual Adjust Yield Calibration Factor
NOTE:
Do not perform a manual adjust Calibration Factor if you intend on using the Low Flow calibration.
Use the following example to figure a New Calibration Factor:
Displayed Calibration Factor = 650
Weight of grain shown on display = 12,539 kg (27,643 lb.)
Net weight of grain from scale ticket = 12,257 kg (27,022 lb.)
New Calibration Factor = 665
|