Every 250 Hours

H93396
H86835
H86837


A-Cap
B-Drain


C-Dipstick


D-Fuel Tank Breather


E-Hose

IMPORTANT: Change oil every 100 hours if fuel is more than 0.5 % sulfur.

Fill crankcase with seasonal viscosity grade oil or Torq-Gard Supreme ™ (250 hours change interval). If using Plus-50 ™ oil and a John Deere filter, service interval can be extended by 50 percent. Example: 250 Hours extends to 375 Hours.

1. Engine Crank Case Top Load Oil Filter - Remove cap (A) and remove filter. Replace filter and install cap. Tighten cap to specifications.

Specification

Oil Filter Cap -Torque 40 N·m (30 lb-ft)

2. Engine Crank Case Top Load Oil - Open drain (B) to remove oil.

Torq-Gard Supreme is a trademark of Deere & Company
Plus-50 is a trademark of Deere & Company

OUO6075,00002E2 -19-05FEB09-1/2


3. Engine Crank Case Top Load Oil - Remove dipstick (C) to fill and check oil level after filling.

4. Fuel Tank Breather - Visually inspect fuel tank breather (D). Do not allow debris to collect on

breather. Remove fuel tank breather from hose (E) and clean.

OUO6075,00002E2 -19-05FEB09-2/2