Unloading Auger Position-Adjusting (High Unload Rate Grain Tank)

1. Measure distance from unloading auger edge (A) to grain tank structure (B) as shown.

2. Distance must be set to specification.

Specification

Unloading Auger Edge to Grain Tank Structure -Distance 73 mm (2-7/8 in.)


A-Unloading Auger Edge
B-Grain Tank Frame

H80949

OUO6075,000034A -19-13APR09-1/2


3. If distance is incorrect, remove cap screws (A) and cover (B).

4. Remove cotter pin (C), nut and washer (D), and pin (E).

5. Loosen jam nut (F) and adjust eyebolt (G) to obtain correct distance.

6. Install previously removed hardware and cover after dimensions are set correctly.


A-Cap Screws (8 Used)
B-Cover
C-Cotter Pin
D-Nut and Washer
E-Pin
F-Jam Nut
G-Eyebolt

H93804

OUO6075,000034A -19-13APR09-2/2