Cleaning Fan Speed Adjust Switch (Black)

Cleaning fan speed adjust switch (A) will increase cleaning fan speed or decrease cleaning fan speed as determined by operator.

1. Turn separator engage switch ON.

2. Press cleaning fan speed adjust switch.

3. Indicator light (B) will come on indicating setting can be adjusted.

4. Turn selection dial (C) towards plus (+) symbol to increase cleaning fan speed or towards minus (-) symbol to decrease cleaning fan speed.

5. CommandCenter display will show operator adjustment setting.

Fan speed motor has a thermal (heat) shut off that stops the motor from working if any of the following happen:

  • Switch is used continuously for more than two or three minutes.
  • Adjustment system is against stop while motor is still trying to change speed.
  • Excessive binding or dragging in linkage.

If any of the above causes are suspected, clean and adjust as necessary.

NOTE: Allow motor to cool 10 to 15 minutes before trying switch again.

H86955


A-Cleaning Fan Speed Adjust Switch
B-Indicator Light
C-Selection Dial

OUO6075,00005ED -19-30MAR07-1/1