Standard Speed High Capacity Feed Accelerator-Changing
NOTE:
When changing separator speeds make sure to cycle power ON and OFF. Combine will now recognize the new speed range.
To change feed accelerator speed to high speed position:
-
Remove belt tension by pushing lever (A) up and out from notch in bracket (B).
-
Move belt (C) to inside sheave grooves on both sheaves for high speed.
-
Push lever up and into notch in bracket to reset belt tension.
A-Lever
B-Notch in Bracket
C-Belt
|