Unloading Auger Drive Belt-Replacing

causym CAUTION: Shut OFF engine, set parking brake and remove key.

Be certain drive is disengaged and hydraulic cylinder (A) is retracted.

Loosen tensioner (B) on unloading auger drive chain.

Remove chain from driver sprocket (C) on countershaft.

Remove cap screws retaining belt trap (D).

Remove belt trap and belt (E).

Install replacement belt and replace belt trap previously removed.

Install drive chain and adjust idler until washer aligns with end of gauge.


A-Hydraulic Cylinder
B-Tensioner
C-Sprocket
D-Belt Trap
E-Belt

H54696
H54697

Standard Grain Tank Tensioner

H87818

High Unload Rate Tensioner

H54698

OUO6075,00007D1 -19-23APR07-1/1