CLIMATRAK High Pressure Switch

A high pressure condition can result from insufficient air flow across the condenser. When this happens, switch (A) (next to radiator) shuts off the compressor.

Stop combine, set parking brake and remove key.

Clean condenser, filters and check for broken fan belt.

Start engine and turn ON air conditioning. If switch shuts off compressor again, see your John Deere dealer.


A-High Pressure Switch

H71205