Change oil every 100 hours if fuel is more than 0.5 % sulfur.
Fill crankcase with seasonal viscosity grade oil or Torq-Gard Supreme (250 hours change interval). If using Plus-50 or Plus-50 II oil and a John Deere filter, service interval can be extended by 50 percent. Example: 250 Hours extends to 375 Hours.
Engine Crank Case Oil Filter - Remove and replace oil filter (A).
Engine Crank Case Oil - Open drain (B) to remove oil.
Engine Crank Case Oil - Remove cap (C) to fill and check oil level with dipstick (D) after filling.
Fuel Tank Breather - Visually inspect fuel tank breather (E). Do not allow debris to collect on breather. Remove fuel tank breather from hose (F) and clean.
Torq-Gard Supreme is a trademark of Deere & Company Plus-50 is a trademark of Deere & Company