Change oil every 100 hours if fuel contains more than 0.5 % (or 5000 ppm) sulfur.
Fill crankcase with seasonal viscosity grade oil or Torq-Gard (250 hours service interval). If using Plus-50 or Plus-50 II engine oil and a John Deere filter, service interval can be extended by 50 percent. Example: 250 Hours extends to 375 Hours.
Engine Crankcase Oil - Open drain (B) to remove oil.
Engine Crankcase Oil - Remove cap (C) to fill and check oil level with dipstick (D) after filling.
Fuel Tank Breather - Visually inspect fuel tank breather (E). Do not allow debris to collect on breather. Remove fuel tank breather from hose and clean.
Torq-Gard is a trademark of Deere & Company Plus-50 is a trademark of Deere & Company